My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
02-24-1997 Council Packet
Orono
>
City Council
>
1997
>
02-24-1997 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2023 3:04:10 PM
Creation date
7/31/2023 3:02:06 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
p <br />TO;Jeanne A. Mabusth, Planning and Zoning Administrator <br />FROM:Stephen Weckman, On-Site Systems Manager <br />DATE:January 10, 1997 <br />SUBJECT: Septic Review for Application #2204, Fullerton Estates - Subdivision <br />The proposed five lot subdivision includes four existing septic systems. All of the existing septic <br />systems are non-compliant (failing) due to the lack of three foot separation between the drainfield <br />and the seasonal water table. Although none are an eminent health hazard currently, each of them <br />must be replaced at this time or be properly abandoned. For this reason each of the new lots has <br />both primary and alternate drainfield sites located on them. The existing septic systems serve 3350 <br />Fox St., 3400 Fox St., the caretaker residence, and the garage facility. <br />All proposed septic systems meet City and State standards. The drainfield sites are designed for five <br />bedroom residences on lots 1, 2, and 5, while lots 3 and 4 have eight bedroom designs to <br />accommodate the large existing main residences and a caretaker residence. <br />The drainfield sites on lots 1,2 , and 5 must all be fenced off prior to any grading or land alteration <br />due to their proximity to the access road. Also, the driveway for each of these lots will pass 20 feet <br />from many of the drainfield sites, so the sites must be accurately fenced to protect them from <br />damage. <br />Based on the above information, staff recomends approval of the application. The applicant should <br />note that the 20 foot setback between the drainfield areas and the driveway must be maintained. <br />i
The URL can be used to link to this page
Your browser does not support the video tag.