Laserfiche WebLink
Paul Hanson <br />September 24, 1998 <br />Page 2 of 3 <br />2. The follou ing observations w ere made with respect to the foundation of the boatliouse: <br />3. <br />a. <br />b. <br />c. <br />d. <br />e. <br />f <br />The foundation is an 8" thick concrete masonry foundation system. <br />The boathouse is built in the side of the hall with grade at the roof line at the rear <br />and grade at the slab height at the front with grade sloping along the side walls. <br />The structure is ten courses high (7'-4"). The slab on grade provides space <br />approximately 10 feet deep witli a transverse wood frame wall at tliis location <br />with backfill approximately 3'-8" above the slab sloping up to the rear foundation <br />approximately 6 feet away. <br />No exploratory work was done to deienninc tlic depth of the footings. <br />Horizontal cracks exist in the masonry side walls indicating frost heave with the <br />wall out of level approximately 1/2" over its length. <br />The rear foundation wall is severely damaged due to excessive earth pressure and <br />frost heave. <br />The following corrective measures are required in order to provide a structurally sound <br />foundation conforming with the Minnesota State Building Code: <br />a. Reconstruct the rear wall with 12" block on 16" x 8" fooling a minimum of 5 feet <br />below grade. Reinforce with #4 @ 32" vertical in center of wail with hook dow'cl <br />into footing. <br />b. Remove wood frame wall and constmet new masonry wall 8" thick on 16" x 8" <br />footing wth top of footing 4" below bottom of floor slab. Reinforce with #4 @ 32" <br />vertical in center of wall with hook dowel into footing. Tie this wall to existing <br />pilasters in side wall with /r4 dowels @ 16" O.C. grouted in place. <br />c. Underpin front foundation wall and side walls to provide a minimum of 5 feet to <br />bottom of footing on exterior grade. Underpiiming to be done in accordance with <br />standard practice 4 feet wide strips. <br />d. Tuckpoint and repair cracked block and other masomy to provide a solid wall. <br />e. Tooth rear wall to side walls to provide a rigid wall system. <br />f. Construct w'ood roof system using standard carpentry procedures with roof plate <br />anchored to masonry wall in accordance wiilt the Code. <br />g. Provide wood blocking @ 24" O.C. in first two joist spaces %%ilh nailing to rear wall <br />top plate in accordance with the Code. <br />4.Since the boathouse is a utility structure, protection against frost on the interior is not <br />recommended or required in my opinion.