Laserfiche WebLink
TABLE III: EZ-WIRE SYSTEM CENI ER SPECinCATlONS <br />MODEL EZ-WIRE 12-48V BAT EZ90/900 EZ120/1600 EZ120/2300 EZ200/2300 EZ200/4600 EZ2S0/7000 <br />Standard wind generator model <br />Standard shipping volts <br />User-selectable voltages <br />DC wind amps max (diodes) (!) <br />Solar PV amps max(ii) <br />Solar pv on/otf 40amp breakers <br />DC load on/off 40amp breakers <br />Capacitors mfd, 330v start <br />Full metering (111) <br />Wind-gen on/off brake switch(iv) <br />Max wind charging watts(v) <br />Max solar charging watts(vi) <br />Max tot bat charging watts <br />Diversion load watts(vii &viii) <br />MODEL EZ-WIRE 64-240V BAT <br />H500/600 H900/1000 HI 500 <br />12 24 24 <br />12.24.32.36.48 12.24,32.36.48 12.24.32.36.48 <br />H15001vl2only <br />12 <br />12.24,32,36.48 <br />3000 <br />48 <br />24,32,36.48 <br />H4500 <br />48 <br />24,32,36.48 <br />50 80 80 120 120 170 <br />40 40 40 80 80 80 <br />1 1 1 2 2 2 <br />1 1 1 1 1 1 <br />40 60 6C 120 120 120 <br />yes yes yes yes yes yes <br />yes yes yes yes yes yes <br />3000 4800 4800 7200 7200 10200 <br />2400 2400 2400 4800 4800 4800 <br />5400 7200 7200 12000 12000 15000 <br />900 <br />EZHVl <br />1600 <br />EZHV2 <br />2300 2300 4600 7000 <br />Wind generator hv model 1000/H1500 3000/H4500 <br />DC wind amps max(i)50 70 <br />Capacitors mfd. 350v run 35 55 <br />Wind-gen on/off brake switch yes yes <br />EZ-WIRE 3phase 240v hcadng EZ230AH1 EZ230AH2 <br />Wind generator hv model 1000/H1500 3000/H4500 <br />AC amp rating relay per leg 13 20 <br />Max watts per phase, 240vac 1500 2500 <br />Capacitors mfd, 350v run 10 35 <br />Wind-gen on/off-brake switch yes yes <br />EZ-WIRE ELECTRIC PUMP EZPMPl EZPMP2 <br />Wind generator hv model 1000 3000 <br />AC amp rating relay per leg 13 20 <br />3 phase motor honepower 3/4 2 <br />Capacltois mfd, 350v run 35 55 <br />Wind-gen on/off-brake switch yes yes <br />Pump hydraulic hp 3400rpm (ix)1/2 1.5 <br />Cut-in hz/rpm 30/1700 30/1700 <br />Max hz/rpm 80/4500 80/4500 <br />9" s’v 1 •> • / V < <br />wr-’T'-r' <br />Xi * <br />NOTES: <br />(i) This input is 3phase ac such as wind, hydro or alternator to full wave bridge. Input shorting switch provided for brake. <br />(ii) This input is dc such as PV, generator or banery charger with one or two 40amp switch/circuit breaker. <br />(iii) Meter functions: State of battery charge, battery volts, net bat amps, wind gen amps, pv amps, dc load amps. ^ <br />(lv)WlND ON/OFF switch is on transformer cabinet on hvlv models. Some 3000 and H4500 have external brake switch. <br />(v) Max watts is 48v battery at full 60v times diode rated current. <br />(vi) Max solar watts is 48v batteiy at full 60v times 40amp (breaker rating). <br />(vii) Diversion load watts is at full banery voltage (2.5volts per cell). Your input (wind and solar) wanage may exceed divenion load capacity (except 32v sening) <br />but you may have to turn off either the wind or solar manually to prevent overcharging battery. (Total input -vatts must not exceed diversion load watts at 32v.) <br />The total of both wind and solar inputs should be less than 110% of diversion load rating for proper regulation with both inputs present. <br />The wiiicl or solar wattage individually should each be less than 110*/b of diversion load rating for proper regulator operation with one source charging. <br />(viii) Total input watts must not exceed diversion load watts on 32volt systems. Diversion load rating is 60% of figure on 36voIt systems. <br />(ix)Pump load will be twice nominal hydralic horsepower, and rpm is about 4500 at governing wind speed.