My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-21-1998 Planning Packet
Orono
>
Planning Commission
>
1998
>
09-21-1998 Planning Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2023 1:28:11 PM
Creation date
7/27/2023 1:21:46 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TABLE III: EZ-WIRE SYSTEM CENI ER SPECinCATlONS <br />MODEL EZ-WIRE 12-48V BAT EZ90/900 EZ120/1600 EZ120/2300 EZ200/2300 EZ200/4600 EZ2S0/7000 <br />Standard wind generator model <br />Standard shipping volts <br />User-selectable voltages <br />DC wind amps max (diodes) (!) <br />Solar PV amps max(ii) <br />Solar pv on/otf 40amp breakers <br />DC load on/off 40amp breakers <br />Capacitors mfd, 330v start <br />Full metering (111) <br />Wind-gen on/off brake switch(iv) <br />Max wind charging watts(v) <br />Max solar charging watts(vi) <br />Max tot bat charging watts <br />Diversion load watts(vii &viii) <br />MODEL EZ-WIRE 64-240V BAT <br />H500/600 H900/1000 HI 500 <br />12 24 24 <br />12.24.32.36.48 12.24,32.36.48 12.24.32.36.48 <br />H15001vl2only <br />12 <br />12.24,32,36.48 <br />3000 <br />48 <br />24,32,36.48 <br />H4500 <br />48 <br />24,32,36.48 <br />50 80 80 120 120 170 <br />40 40 40 80 80 80 <br />1 1 1 2 2 2 <br />1 1 1 1 1 1 <br />40 60 6C 120 120 120 <br />yes yes yes yes yes yes <br />yes yes yes yes yes yes <br />3000 4800 4800 7200 7200 10200 <br />2400 2400 2400 4800 4800 4800 <br />5400 7200 7200 12000 12000 15000 <br />900 <br />EZHVl <br />1600 <br />EZHV2 <br />2300 2300 4600 7000 <br />Wind generator hv model 1000/H1500 3000/H4500 <br />DC wind amps max(i)50 70 <br />Capacitors mfd. 350v run 35 55 <br />Wind-gen on/off brake switch yes yes <br />EZ-WIRE 3phase 240v hcadng EZ230AH1 EZ230AH2 <br />Wind generator hv model 1000/H1500 3000/H4500 <br />AC amp rating relay per leg 13 20 <br />Max watts per phase, 240vac 1500 2500 <br />Capacitors mfd, 350v run 10 35 <br />Wind-gen on/off-brake switch yes yes <br />EZ-WIRE ELECTRIC PUMP EZPMPl EZPMP2 <br />Wind generator hv model 1000 3000 <br />AC amp rating relay per leg 13 20 <br />3 phase motor honepower 3/4 2 <br />Capacltois mfd, 350v run 35 55 <br />Wind-gen on/off-brake switch yes yes <br />Pump hydraulic hp 3400rpm (ix)1/2 1.5 <br />Cut-in hz/rpm 30/1700 30/1700 <br />Max hz/rpm 80/4500 80/4500 <br />9" s’v 1 •> • / V < <br />wr-’T'-r' <br />Xi * <br />NOTES: <br />(i) This input is 3phase ac such as wind, hydro or alternator to full wave bridge. Input shorting switch provided for brake. <br />(ii) This input is dc such as PV, generator or banery charger with one or two 40amp switch/circuit breaker. <br />(iii) Meter functions: State of battery charge, battery volts, net bat amps, wind gen amps, pv amps, dc load amps. ^ <br />(lv)WlND ON/OFF switch is on transformer cabinet on hvlv models. Some 3000 and H4500 have external brake switch. <br />(v) Max watts is 48v battery at full 60v times diode rated current. <br />(vi) Max solar watts is 48v batteiy at full 60v times 40amp (breaker rating). <br />(vii) Diversion load watts is at full banery voltage (2.5volts per cell). Your input (wind and solar) wanage may exceed divenion load capacity (except 32v sening) <br />but you may have to turn off either the wind or solar manually to prevent overcharging battery. (Total input -vatts must not exceed diversion load watts at 32v.) <br />The total of both wind and solar inputs should be less than 110% of diversion load rating for proper regulation with both inputs present. <br />The wiiicl or solar wattage individually should each be less than 110*/b of diversion load rating for proper regulator operation with one source charging. <br />(viii) Total input watts must not exceed diversion load watts on 32volt systems. Diversion load rating is 60% of figure on 36voIt systems. <br />(ix)Pump load will be twice nominal hydralic horsepower, and rpm is about 4500 at governing wind speed.
The URL can be used to link to this page
Your browser does not support the video tag.