My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-12-2023 Council Packet
Orono
>
City Council
>
2023
>
06-12-2023 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2023 1:49:04 PM
Creation date
6/27/2023 1:45:10 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
8'-1 1/8"0'-10"8'-9 3/4"7'-4 5/8"8'-1 1/8"0'-10"8'-10 1/8"APPROX. 6'-8"NEW BONUS ROOM ROOF BEYOND <br />OFFICEGARAGE <br />LOWER <br />GARAGE <br />BONUS <br />ROOM <br />EXIST'G FLOOR JOISTS TO REMAIN <br />EXIST'G FLOOR JOISTS TO REMAIN <br />MIN. R-49 ATTIC INSULATION <br />EXIST'G TO REMAIN <br />DECK <br />ATTIC- <br />UNCONDITIONED <br />EXIST'G FLOOR JOISTS TO REMAIN <br />ATTIC- <br />UNCONDITIONED <br />EXIST'G TO REMAIN 7 3/4"10" <br />WINDOW SCHEDULE <br />NUMBER QTY FLOOR <br />W01 1 0 <br />W02 1 0 <br />W03 1 0 <br />W04 1 0 <br />W05 1 0 <br />W06 3 1 <br />W07 1 1 <br />W08 1 1 <br />W09 1 1 <br />W10 1 1 <br />W11 1 1 <br />W12 2 1 <br />W13 1 1 <br />W14 1 1 <br />W15 1 2 <br />W16 1 2 <br />W17 1 2 <br />CONSTRUCTION NOTES AND SCOPE OF WORK: <br />1.PROVIDE BONUS ROOM ABOVE GARAGE- VERIFY STRUCTURAL PLANS AND <br />TRUSS DESIGN. <br />2.INTERIOR WALLS TO BE 4" STUDS WITH GYP BOTH SIDES, TYP. EXTERIOR <br />WALLS AND INTERIOR BEARING WALLS TO BE 6" STUDS WITH GYP <br />INTERIOR AND SIDING EXTERIOR, TYP. <br />3.PROVIDE RADON VENT'G AT SEALED SUMP BASKET, THROUGH ROOF. <br />PROVIDE ONE ELEC OUTLET IN ATTIC NEAR RADON VENT EXIT, PER CODE. <br />4.PROVIDE CONTINUOUS HANDRAIL ONE SIDE OF STAIR, 34-38" ABOVE STAIR <br />NOSING, AS REQ'D. <br />5.PROVIDE SMOKE DETECTOR IN ALL BDRMS AND HALLWAY LEADING TO <br />BDRM(S), AND ONE EACH FLOOR LEVEL AS REQ'D BY CODE. <br />6.PROVIDE 1/2" GYP. BD. ON WALL BETWEEN GARAGE AND HOUSE, ON ALL <br />GARAGE WALLS SUPPORTING BONUS ROOM, ON GARAGE CEILING BELOW <br />BONUS ROOM, AND ON UNDERSIDE OF STAIR BUMP OUT IN GARAGE. <br />7.PROVIDE ONE EGRESS WINDOW EACH BEDROOM AND AT LEAST ONE EACH <br />FLOOR LEVEL. <br />8.PROVIDE BLK'G IN WALLS AT STAIR HANDRAIL, CLOSET SHELVING, TOWEL <br />RODS, ETC. <br />9.PROVIDE FLASHING AT WINDOWS, DOORS, AND ROOF AS REQ'D. <br />10.PROVIDE FIRE BLOCKING IN STUD CAVITIES FOR ANY WALLS OVER 10' IN <br />HEIGHT. <br />11.PROVIDE TEMPERED GLASS AT ANY WINDOW REQUIRING IT PER CODE. <br />12.HEADERS, POSTS, AND BEAMS AS SPECIFIED BY STRUCTURAL ENGINEER. <br />13.ALL ENGINEERING AND PRODUCT MANUFACTURER INFORMATION/ SPECS/ <br />DRAWINGS/ PLANS/ NOTES SUPERSEDE THESE PLANS. <br />WALL SCHEDULE <br />2D SYMBOL WALL TYPE <br /> INTERIOR-4, NEW <br /> BRICK-4, NEW <br /> SIDING-6, NEW <br /> INTERIOR-6, NEW <br /> INTERIOR RAILING <br /> DECK RAILING/FENCE <br /> GLASS SHOWER, NEW <br /> 8" CONCRETE STEM WALL <br /> INTERIOR-6, EXIST'G <br /> INTERIOR-4,EXIST'G <br /> SIDING-6, EXIST'G <br /> 12" CONCRETE STEM WALL <br /> 8" CMU (BLOCK) STEM WALL, EXIST'G <br />FLASH AROUND PIPE <br />VENT PIPE RUNS VERTICALLY <br />THRU THE BLDG. <br />LABEL PIPE AS "RADON <br />REDUCTION SYSTEM" @ EA. <br />FLOOR <br />6 MIL POLY SHEETING OVER <br />AGGREGATE, LAPPED 12" @ <br />SEAMS, FIT CLOSELY AROUND <br />PENETRATIONS <br />4" OF AGGREGATE ( 1/4"< <br />AGGREGATE DIA < 2") UNDER ALL <br />CONC. SLABS <br />PIPE ENDS MIN. 12" <br />ABOVE ROOF SURFACE <br />AND MIN 10'-0" FROM <br />WINDOWS, OPENINGS, OR <br />OTHER BUILDINGS <br />VENT PIPE <br />T-FITTING VENT PIPE TO <br />HORIZ. PIPE <br />3-4" PERF. PIPE LAID <br />HORIZ. UNDER V.B. IN <br />AGGREGATE <br />MIN. TREAD <br />MAX RISER1.MIN 6'-8" HEADROOM <br />MEASURED FROM <br />DIAGONAL OF STAIR <br />NOSINGS. <br />2.MAINTAIN MIN 36" WIDTH <br />AT HALLWAYS AND <br />STAIRWAYS. <br />3.PROVIDE MIN ONE <br />CONTINUOUS, GRIPPABLE <br />HANDRAIL AT STAIRS, W/ <br />ENDS RETURNING TO <br />WALL OR POST. HANDRAIL <br />TO BE 34"-38" HIGH, 1-1/4" <br />DIA, AND NO CLOSER <br />THAN 1-1/2" TO WALL. <br />4.GUARDRAILS MIN 36" HIGH <br />W/ MAX 4" OPENING. <br />HANDRAIL <br />TYPICAL RADON DETAIL <br />NOT TO SCALE <br />TYPICAL STAIR DETAIL <br />NOT TO SCALE <br />(MAYHAVEFNDN.) <br />(MAYHAVEFNDN.) <br />(MAYHAVEFNDN.) <br />TO STAIRWELL <br />BEYOND <br />D05D05D05D05 <br />11'-0"3'-0"TV <br />GAS F/P <br />CASED BEAMS <br />VERIFY SHELF AND <br />BUILT-IN PLACEMENT <br />WITH CABINET SUPPLIER <br />VERIFY STONE <br />VENEER <br />SELECTION 8'-0"COFFEE <br />MICROWAVE <br />WALL <br />OVEN <br />LOCKERS <br />CASED BEAMS <br />A7 <br />SHEET:DRAWINGS PROVIDED BY:DATE: <br />3/22/2023KAREN RIVERSRIVERS DESIGN HOUSE, LLCwww.riversdesignhouse.com763.670.9806REMODEL PLANS FOR:JOHN & LESLIE CADLE2691 ETHEL AVE.WAYZATA, MN 55391CROSS SECTIONS ANDDETAILSFILE NAME:266 CADLE HRIPROJECT # 266SHEET SIZE: 24X36CHIEF ARCHITECT X14HOME REFLECTIONS, INC.1 <br />A7 <br />1 <br />A7 <br />CROSS SECTION THRU BONUS ROOM & GARAGES <br />1/4" : 1'-0" <br />BONUS ROOM ELEVATIONS <br />LOWER LEVEL ELEVATIONS <br />MASTER BATH ELEVATION MUDROOM ELEVATION LAUNDRY ROOM ELEVATION <br />LIVING ROOM ELEVATIONS <br />KITCHEN ELEVATIONS <br />MASTER BEDROOM ELEVATION
The URL can be used to link to this page
Your browser does not support the video tag.