My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
M20-000009 - mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1400 Bracketts Point Road - 11-117-23-32-0025
>
Permits/Inspections
>
M20-000009 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:30:06 PM
Creation date
6/26/2023 11:11:36 AM
Metadata
Fields
Template:
x Address Old
House Number
1400
Street Name
Bracketts Point
Street Type
Road
Address
1400 Bracketts Point Road
Document Type
Permits/Inspections
Permit Number
M20-000009
PIN
1111723320025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Name <br />Brackets Point House <br />Date <br />8/30/2021 <br />Submitted By <br />Tim Harris <br />Software Version <br />10.20 <br />Unit Tag <br />HP -033 - LH <br />W GTV0641 208-230/60/1 2250 <br />Model Number: WGTV064 <br />Unit Type: SmartSource - 2 -Stage <br />Approval: ETL, CETL, AHRI <br />Configuration Refrigerant Type <br />Vertical R -410A <br />15.00 62248 16.1 <br />Refrigerant Weight <br />120.0 oz <br />45272 3.5 <br />Loop Temperature Range <br />Ground Loop (Geothermal) <br />Air & Fluid Flow <br />Airflow <br />Total External Static Pressure Fluid Flow <br />Fluid Type <br />Glycol Concentration Altitude <br />Full (Part) <br />Full (Part) <br />0.30 (15txtSESPFull) 15.00 gpm <br />/ 3.00 <br />2250(2000)CFM <br />propylene Glycol <br />25.0% <br />0 ft <br />inH20 gpm/ton <br />Cooling Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of EER @ <br />Fluid <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Sensible <br />Rejection design <br />Pressure <br />'F <br />°F Dry Bulb Wet Bulb <br />Dry Bulb <br />Wet Bulb <br />Btu/hr <br />Btu/hr <br />Drop <br />Performance <br />°F °F <br />°F <br />°F <br />ft H20 <br />Full Load 77.0 <br />87.5 75.0 63.0 <br />55.3 <br />53.2 62248 <br />48050 <br />75463 16.1 <br />11.46 <br />Part Load 68.0 <br />75.3 70.0 59.0 <br />52.2 <br />50.6 44794 <br />38591 <br />52502 19.8 <br />11.67 <br />Heating Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of <br />COP @ design <br />Fluid Pressure <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Absorption <br />Drop <br />°F <br />°F Dry Bulb <br />Dry Bulb <br />Btu/hr <br />Btu/hr <br />ft Hzo <br />Performance <br />°F <br />°F <br />Full Load 31.0 <br />26.5 70.0 <br />88.5 <br />45272 <br />32328 <br />3.5 <br />12.83 <br />Part Load 41.0 <br />37.1 70.0 <br />87.5 <br />37925 <br />28035 <br />3.8 <br />12.46 <br />*System WPD is calculated without the autoflow valve as the CV of <br />an autoflow valve varies dependent on the system WPD. <br />As long as the WPD is <br />>3 psid, the <br />autoflow valve will provide the selected GPM flowrate. <br />Electrical <br />Unit Voltage <br />Minimum Voltage <br />Total Unit Full Load Current <br />Total Unit MCA <br />208-230/60/1 <br />197 v <br />36.5 A <br />43.3 A <br />Compressor RLA <br />Compressor LRA <br />Motor FLA <br />Maximum Recommended Fuse Size / HACR Breaker Size <br />27.1A <br />152.9A <br />9.4A <br />60A <br />*Short -Circuit Current = <br />5 kA rms symmetrical, 600 V maximum <br />Job Number: LL20FE Page Prepared Date: 8/30/2021 <br />Job Name: Brackets Point House 22 of 26 www.DaikinApplied.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.