Job Name <br />Brackets Point House <br />Date <br />8/30/2021 <br />Submitted By <br />Tim Harris <br />Software Version <br />10.20 <br />Unit Tag <br />HP -018B, HP -101A, HP -124 <br />W GTV0491 208-230/60/1 1800 <br />Model Number: WGTV049 <br />Unit Type: SmartSource - 2 -Stage <br />Approval: ETL, CETL, AHRI <br />Configuration Refrigerant Type <br />Vertical R -410A <br />12.00 47921 16,35651 <br />Refrigerant Weight Loop Temperature Range <br />85.0 oz Ground Loop (Geothermal) <br />Air & Fluid Flow <br />Airflow <br />Total External Static Pressure Fluid Flow <br />Fluid Type <br />Glycol Concentration Altitude <br />Full (Part) <br />Full (Part) <br />1800(1600)CFM <br />0.30 (15txtSESPFull) 12.00 gpm <br />/ 3.00 <br />propylene Glycol <br />25.0% <br />0 ft <br />inH20 gpm/ton <br />Cooling Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of EER @ <br />Fluid <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Sensible <br />Rejection design <br />Pressure <br />'F <br />°F Dry Bulb Wet Bulb <br />Dry Bulb <br />Wet Bulb <br />Btu/hr <br />Btu/hr <br />Drop <br />Performance <br />°F °F <br />°F <br />°F <br />ft H20 <br />Full Load 77.0 <br />87.1 75.0 63.0 <br />55.8 <br />53.6 47921 <br />37586 <br />58036 16.2 <br />7.11 <br />Part Load 68.0 <br />75.0 70.0 59.0 <br />53.1 <br />50.9 34737 <br />29336 <br />40580 20.3 <br />7.24 <br />Heating Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of <br />COP @ design <br />Fluid Pressure <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Absorption <br />Drop <br />°F <br />°F Dry Bulb <br />Dry Bulb <br />Btu/hr <br />Btu/hr <br />ft Hzo <br />Performance <br />°F <br />°F <br />Full Load 32.0 <br />27.6 70.0 <br />88.2 <br />35651 <br />25660 <br />3.6 <br />7.93 <br />Part Load 41.0 <br />37.3 70.0 <br />86.7 <br />29070 <br />21573 <br />3.9 <br />7.73 <br />*System WPD is calculated without the autoflow valve as the CV of <br />an autoflow valve varies dependent on the system WPD. <br />As long as the WPD is <br />>3 psid, the <br />autoflow valve will provide the selected GPM flowrate. <br />Electrical <br />Unit Voltage <br />Minimum Voltage <br />Total Unit Full Load Current <br />Total Unit MCA <br />208-230/60/1 <br />197 v <br />28.5 A <br />33.8 A <br />Compressor RLA <br />Compressor LRA <br />Motor FLA <br />Maximum Recommended Fuse Size / HACR Breaker Size <br />21.2A <br />104.0A <br />7.3A <br />50A <br />*Short -Circuit Current = <br />5 kA rms symmetrical, 600 V maximum <br />Job Number: LL20FE <br />Job Name: Brackets Point House <br />Page Prepared Date: 8/30/2021 <br />16 of 26 www.DaikinApplied.com <br />