Laserfiche WebLink
Technical Data Sheet for 2 Ton Horizontal - LH <br />Job Name <br />Brackets Point House <br />Date <br />8/30/2021 <br />Submitted By <br />Tim Harris <br />Software Version <br />10.20 <br />Unit Tag <br />HP -007, HP -010 <br />W GTH 0261 208-230/60/1 800 <br />Model Number: WGTH026 <br />Unit Type: SmartSource - 2 -Stage <br />Approval: ETL, CETL, AHRI <br />Configuration Refrigerant Type <br />Horizontal R -410A <br />6.00 25409 17.5 = 17874 <br />Refrigerant Weight Loop Temperature Range <br />56.0 oz Ground Loop (Geothermal) <br />Air & Fluid Flow <br />Airflow <br />Total External Static Pressure Fluid Flow <br />Fluid Type <br />Glycol Concentration Altitude <br />Full (Part) <br />Full (Part) <br />0.30 (15txtSESPFull) 6.00 gpm / 3.00 <br />800(700)CFM <br />propylene Glycol <br />25.0% <br />0 ft <br />inH20 gpm/ton <br />Cooling Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of EER @ <br />Fluid <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Sensible <br />Rejection design <br />Pressure <br />'F <br />°F Dry Bulb Wet Bulb <br />Dry Bulb <br />Wet Bulb <br />Btu/hr <br />Btu/hr <br />Drop <br />Performance <br />°F °F <br />°F <br />°F <br />ft H20 <br />Full Load 77.0 <br />87.5 75.0 63.0 <br />52.8 <br />51.6 25409 <br />19301 <br />30364 17.5 <br />5.90 <br />Part Load 68.0 <br />75.5 70.0 59.0 <br />51.2 <br />48.9 18714 <br />14300 <br />21656 21.7 <br />6.01 <br />Heating Performance <br />Fluid Temperature Air Temperature <br />Capacity <br />Heat of <br />COP @ design <br />Fluid Pressure <br />Entering <br />Leaving Entering <br />Leaving <br />Total <br />Absorption <br />Drop <br />°F <br />°F Dry Bulb <br />Dry Bulb <br />Btu/hr <br />Btu/hr <br />ft Hzo <br />Performance <br />°F <br />°F <br />Full Load 32.0 <br />27.5 70.0 <br />90.6 <br />17874 <br />13049 <br />3.7 <br />6.59 <br />Part Load 41.0 <br />37.1 70.0 <br />89.8 <br />15043 <br />11300 <br />4.0 <br />6.42 <br />*System WPD is calculated without the autoflow valve as the CV of <br />an autoflow valve varies dependent on the system WPD. <br />As long as the WPD is <br />>3 psid, the <br />autoflow valve will provide the selected GPM flowrate. <br />Electrical <br />Unit Voltage <br />Minimum Voltage <br />Total Unit Full Load Current <br />Total Unit MCA <br />208-230/60/1 <br />197 v <br />14.7 A <br />17.6 A <br />Compressor RLA <br />Compressor LRA <br />Motor FLA <br />Maximum Recommended Fuse Size / HACR Breaker Size <br />11.7A <br />58.3A <br />3.0A <br />25A <br />*Short -Circuit Current = <br />5 kA rms symmetrical, 600 V maximum <br />Job Number: LL20FE <br />Job Name: Brackets Point House <br />Page Prepared Date: 8/30/2021 <br />4 of 26 www.DaikinApplied.com <br />