My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info including design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
460 Big Island - PID: 23-117-23-32-0002/0010/0011/0012/0046/0047/0048/0049
>
Septic
>
Septic info including design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:59 PM
Creation date
9/30/2015 10:59:04 AM
Metadata
Fields
Template:
x Address Old
House Number
460
Street Name
Big Island
Address
460 Big Island
Document Type
Septic
PIN
2311723320002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � � <br /> � O� <br /> � ;:;� O <br /> =1���.��� CI�'Y of OR011TU <br /> �: �: <br /> ���:�._ ... , � <br /> � �� }�s�,��,�. � <br /> '�'+, ��; �";' f� Municipal Offices <br /> � � � Ij��a�� �'�' <br /> .Z �'�;`��"�����i Street Address: Mailing Address: <br /> .i"y�!I <br /> .9kE$�IOg' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay; MN 55323-0066 <br /> Owner: IVG���r F a(' n e5 Address:_ 3�� Q��q �5�a n� <br /> Cit�•Ordinance 199 requires that each esisting on-site sewage treatment system in Orono be inspected every rivo years. <br /> The on-site se�vage treatment system at the above address has been inspected and appears to fall into the categories checked below.' <br /> SYSTEM CONF'ORMITY (1-3): 1 <br /> Ol ��CODE SYSTEM° An ISTS which meets all the location,design and construction standards of the current Qrono bfunicipal Codz. <br /> 2 ��CONIPLIAN'T SYSTEM�� An ISTS which does not meet all the location,design and construclion standards ofthe current Orono Municipal <br /> Code but dozs meet the three foot sepazation requuement,and which is not failing or an imminent threat to public heahh or safety. <br /> 3 °NON-CO�fF'LIANT SYSTEM° A prohibited ISTS;an ISTS located within a dzsignated 100-yeaz flood plaiq any ISTS which may <br /> or may not mzet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less thanthree fzet of unsaturatzd soil or sand between the distribution device and the luniting soil chazactzris[ics. <br /> TANI,'.CONDITION(�-10): 5 - <br /> Tanl�inspection indicates: <br /> OPumpout nut nzeded at this timz. <br /> 6 Tank must be pumpzd out this year (city code requires tanks to be pumped out evzry 3 years. Tank w�s last pumped_ ), <br /> 7 Solids accumulation in tanks is at a crilical a critical level. Tanks should be pumped out as soon as possible. <br /> S System is discharging to thz surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not bz inspected. Inspection risers(4"dia.pipe)must be installed in each tank at nest pumpout If tanks <br /> havz not bezn pumped out within the last three yeacs,they should be pumped out now. <br /> 1� Inspection pipz is locatzd directly over tank bagle(does not givz accuratz mzasurzmznt of solids accumulation). Iftanks have not been pumped <br /> out within the last three years,they should be pumped out now. . <br /> DRAINFIELD CO�IDITION(11-1=�): 1 l <br /> 1 1 Drainfield is dry,no surfacin�evident <br /> 12 Some evidznca of surfacing,not critical ye� . � , <br /> 13 Drainfield is saturated and visibly discharging untreatzd e$luznt to thz surface. Contact the City Inspzctor immediately.Repairs must be <br /> completzd within 90 days. <br /> 1=� Drainfield e.Yeent and condition unkno�tin. <br /> COM��NTS: ��5�-�1\\e� '� n Iq9� <br /> S-9 -o� G�� <br /> Date of Insoection Seplic System Inspector " <br /> Notz: In the evznt that this inspection repoR is tued to satisfy tjie requuemenfs for a mortgage or other transfer of property,be advised that tfiis report does not guarantze <br /> or certify that an esisting systzm will continue to function properly,but is metely an opinion of tha adequacy of the system under curre�conditions based oa the available <br /> informatioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.