Existing First Floor0' - 0" <br />Existing Second Floor <br />10' - 6 1/2" <br />Roof18' - 7 5/8"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"EXISTING 2X10 FLOOR SYSTEM <br />EXISTING CRAWL SPACE <br />Exst.New <br />3/4" SUBFLOOR <br />18" FLOOR TRUSSES @ 19.2" O.C.8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"Heel30 1/4"3' - 0" <br />14 <br />4 <br />3' - 6"2' - 0 3/4"8' - 7 3/4"6 1/4"7' - 0"2' - 6" <br />BEAM FLUSHED <br />PER MFG. SPEC. <br />NEW ROOF TRUSSES <br />PER MFG. SPEC. <br />NEW ROOF TRUSSES <br />PER MFG. SPEC. <br />8" <br />12" <br />FRONT <br />PORCH <br />PORCH FLAT ROOF: <br />EPDM RUBBER MEMBRANE <br />RIGID INSULATION @ 1/4" SLOPE <br />3/4" SHEATHING <br />24" ROOF TRUSSES @ 24" O.C. <br />OPT. PINE T&G CLG. <br />FAMILY <br />ROOM <br />FOYER <br />BDRM #2NEW LOFT <br />New <br />BEAM FLUSHED <br />PER MFG. SPEC. <br />NOTE: <br />PROVIDE EXISTING CRAWL SPACE <br />& FOUNDATION AREA TO BE <br />SEALED WITH VAPOR BARRIER <br />22' - 2 1/2"10' - 8 1/2" <br />GIRDER TRUSS <br />PER MFG. SPEC. <br />New First Floor Clg.8' - 11 3/4" <br />EXST. DECK4"Existing Second Floor <br />10' - 6 1/2" <br />Roof18' - 7 5/8" <br />Lowered First Floor-0' - 6 1/4"8' - 1 1/8"1' - 6 3/4"9' - 6"Heel11 3/8"Heel30 1/4"3 1/2" <br />12" <br />8" <br />12"8' - 1 1/8"1' - 6 3/4"9' - 6"3/4" SUBFLOOR <br />18" FLOOR TRUSSES @ 19.2" O.C. <br />BEAM FLUSHED <br />PER MFG. SPEC.3' - 6"2' - 0 3/4"9' - 2"NEW ROOF TRUSSES <br />PER MFG. SPEC. <br />New <br />BEAM FLUSHED <br />PER MFG. SPEC. <br />FRONT <br />PORCH <br />PORCH FLAT ROOF: <br />EPDM RUBBER MEMBRANE <br />RIGID INSULATION @ 1/4" SLOPE <br />3/4" SHEATHING <br />24" ROOF TRUSSES @ 24" O.C. <br />OPT. PINE T&G CLG. <br />9' - 6" <br />GUEST RMLAKE <br />BATH <br />BDRM #3 BDRM #4 <br />2' - 0" <br />3' - 0" <br />14 <br />4 Sim <br />NOTE: <br />PROVIDE NEW CRAWL SPACE & <br />FOUNDATION AREA TO BE SEALED <br />WITH VAPOR BARRIER. MATCH <br />EXISTING <br />22' - 2 1/2"10' - 8 1/2" <br />New First Floor Clg.8' - 11 3/4"4"NEW 2x10 JOISTS TO MATCH EXISITNG FLOOR SYSTEM <br />NEW CRAWL SPACE <br />NEW DROPPED BEAM PER MFG. SPEC. <br />Existing First Floor <br />0' - 0" <br />Existing Second Floor10' - 6 1/2" <br />Roof <br />18' - 7 5/8" <br />Exst. Raised First Floor1' - 6" <br />Exst. Raised First Floor Clg.9' - 10 1/2"8' - 1 1/8"8"8' - 4 1/2"29' - 0"8' - 1 1/8"8"8' - 4 1/2"8"EXISTING 2X8 FLOOR SYSTEM <br />EXISTING CRAWL SPACE <br />EXISTING 2X8 FLOOR SYSTEM2' - 0 3/4"8' - 7 3/4"6 1/4"PORCH FLAT ROOF: <br />EPDM RUBBER MEMBRANE <br />RIGID INSULATION @ 1/4" SLOPE <br />3/4" SHEATHING <br />24" ROOF TRUSSES @ 24" O.C. <br />OPT. PINE T&G CLG.3' - 6"12"12" <br />NEW ROOF TRUSSES PER MFG. SPEC. <br />Exst.Exst.New <br />EXST. <br />MECH <br />KITCHENPOCKET <br />OFFICE FRONT PORCH <br />OPEN TO KITCHEN BELOWOWNER'S <br />BATH <br />28' - 10"36' - 5 1/2" <br />NOTE: <br />PROVIDE EXISTING CRAWL SPACE <br />& FOUNDATION AREA TO BE <br />SEALED WITH VAPOR BARRIER <br />3' - 0"11 11/16"2X4 LOOKOUTS <br />2X <br />4 <br /> <br />T <br />R <br />U <br />S <br />S <br /> <br />T <br />A <br />I <br />L <br />S <br />Energy Heel30 1/4"METAL DRIP EDGE <br />5/4" x 8" COMP. FASCIA <br />3/4" BACKING <br />4/4" x 12" COMP. FASCIA <br />17-1/2" x 1-1/4" RIM <br />BOARD SUB FASCIA <br />COMPOSITE VENTED SOFFITS <br />8" <br />12" <br />DRAWN BY <br />DESCRIPTION PROJECT # <br />PROJECT ISSUE <br />RE-ISSUE <br />BUILDER a18476 KENRICK AVE. SUITE #202 <br />LAKEVILLE, MN 55044 <br />TEL: 952.428.8200 <br />EM: Dave@DavidCharlezDesigns.com <br />D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S <br />Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of <br />the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, <br />quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction <br />issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or <br />other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer <br />and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size <br />are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be <br />flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific <br />manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with <br />local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult <br />builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design <br />retains rights to all plans and detail shown. <br />2/16/2023 3:37:56 PM 14Cross Sections MISC - Beduhn - CD <br />Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM <br />1340 Vine Place <br />Orono, MN <br /> 1/4" = 1'-0" <br />1Section - Family Rm/Front Porch <br /> 1/4" = 1'-0" <br />2 Section - Lake Bath/Front Porch <br /> 1/4" = 1'-0" <br />3Section - Pocket Office/Front Porch <br /> 1" = 1'-0" <br />4 Detail - Eave @ New Loft <br />IMPORTANT REMODEL NOTE: <br />VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY <br />FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR <br />STARTING CONSTRUCTION <br />ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING <br />ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING <br />VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, <br />FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR <br />STARTING CONSTRUCTION <br />FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR <br />STARTING CONSTRUCTION <br />ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL <br />BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS <br />STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO <br />CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO <br />THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS <br />REVISION SCHEDULE <br />Number Date Issued by <br />CDRev1 1.18.2023 GM <br />CDRev2 1.24.2023 JCB <br />CDRev3 2.2.2023 GM <br />CDRev4 2.16.2023 LMC