My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7362
Orono
>
Property Files
>
Street Address
>
V
>
Vine Place
>
1340 Vine Place - 07-117-23-42-0031
>
Resolutions
>
Resolution 7362
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:38:31 PM
Creation date
5/25/2023 1:44:51 PM
Metadata
Fields
Template:
x Address Old
House Number
1340
Street Name
Vine
Street Type
Place
Address
1340 Vine Pl
Document Type
Resolutions
Permit Number
LA23-000008
PIN
0711723420031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Existing Upper Level Clg. Hgt.8' - 1 1/8"8"Existing Main Level Clg. Hgt.8' - 4 1/2"8"EXST. 2X8 FLOOR SYSTEM <br />EXST. 2X8 FLOOR SYSTEMEXST. BALCONYNew Energy Heel26 1/4"8" <br />12" <br />3' - 0" <br />NEW ROOF <br />TRUSSES PER <br />MFG. SPEC. <br />EXISTING DECK <br />EXISTING <br />CRAWL SPACE <br />Exst. <br />12 <br />2 <br />New Overhang <br />3' - 0" <br />8" <br />12"New Energy Heel26 1/4"2X <br />6 <br /> <br />T <br />R <br />U <br />S <br />S <br /> <br />T <br />A <br />I <br />L <br />S <br />2X <br />4 <br /> <br />L <br />O <br />O <br />K <br />O <br />U <br />T <br />S <br />Sub Fascia17 1/2"EXST. WALLMETAL DRIP EDGE <br />4/4" x 8" TRIM <br />3/4" BACKING <br />4/4" x 12" FASICA <br />17-1/2" x 1-1/4" SUB FASICA <br />CO <br />M <br />P <br />O <br />S <br />I <br />T <br />E <br /> <br />V <br />E <br />N <br />T <br />E <br />D <br /> <br />S <br />O <br />F <br />F <br />I <br />T <br />S <br />TYPICAL EAVE CONSTRUCTION: <br />ARCHITECTURAL GRADE ASPHALT SHINGLES <br />#15FELT & ICE & WATER SHIELD (6'-0") <br />1/2" OSB SHEATHING w/STEEL CLIPS <br />TRUSSES @ 24" O.C. (PER MFG. SPEC.) <br />BAFFLES w/1" AIR SPACE <br />2X4 LOOKOUTS <br />17-1/2" x 1-1/4" RIM BOARD SUB FASCIA <br />4/4" x 8" FASCIA ON <br />4/4" x 12" COMPOSITE FASCIA <br />COMPOSITE VENTED SOFFITS <br />NEW CRAWL SPACE TO <br />MATCH EXISITNGNew Energy Heel30 1/4"3' - 0" <br />8" <br />12" <br />ROOF, CEILING & EAVE <br />CONSTRUCTION: <br />WALL <br />CONSTRUCTION: <br />FOUNDATION WALL & <br />BASEMENT SLAB <br />CONSTRUCTION: <br />MAIN LEVEL <br />CONSTRUCTION: <br />UPPER LEVEL <br />CONSTRUCTION: <br />ARCHITECTURAL GRADE ASPHALT <br />SHINGLES <br />#15FELT & ICE & WATER SHIELD (6'-0") <br />1/2" OSB SHEATHING w/STEEL CLIPS <br />TRUSSES @ 24" O.C. (PER MFG. SPEC.) <br />BAFFLES w/1" AIR SPACE <br />2X4 LOOKOUTS <br />17-1/2" x 1-1/4" RIM BOARD SUB FASCIA <br />4/4" x 8" FASCIA ON <br />4/4" x 12" COMPOSITE FASCIA <br />COMPOSITE VENTED SOFFITS <br />R-50 BLOWN INSULATION <br />POLY VAPOR BARRIER <br />5/8" GYP. BRD. CEILING <br />3/4" T&G PLYWOOD SUBFLOOR <br />GLUED & SCREWED <br />18" FLOOR TRUSSES @ 19.2" O.C. <br />(FLOOR SYSTEM DESIGNER TO <br />VERIFY SIZE & SPACING BASED ON <br />SPANS) <br />5/8" GYP. BRD. ON CEILING <br />SPRAY INSULATE RIMS (R-21) <br />SIDING PER ELEVATION <br />HOUSE WRAP (WRAP <br />WINDOWS PER MFG. SPEC.) <br />1/2" OSB SHEATHING <br />2X6 STUDS @16" O.C. <br />DBL. TOP PLATE <br />R-21 WALL INSULATION <br />4 MIL POLY VAPOR BARRIER <br />1/2" GYP. BRD. <br />2X6 SOLE PLATE <br />ALL DETAILS TO CONFORM W/ <br />ENERGY CODE <br />AS EXISTING <br />AS EXISTING8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"NEW 2x10 JOISTS TO <br />MATCH EXISTING <br />New <br />3' - 0" <br />2' - 9 1/4"2 3/4" <br />METAL DRIP EDGE <br />5/4" x 8" COMP. FASCIA <br />3/4" BACKING <br />15-1/8" x 1-1/4" RIM <br />BOARD SUB FASCIA <br />15 1/8"4/4" x 10" COMP. FASCIA <br />2X4 BLOCKING <br />CANOPY HANGERS PER ENG. SPEC.BEAM PERMFG. SPEC.2X4 LOOKOUTS <br />2X4 LOOKOUTS <br />EPDM RUBBER MEMBRANE <br />3/4" PLYWOOD (PITCHED @ 1/4" SLOPE MIN.) <br />WEDGE BLOCK <br />COMPOSITE VENTED SOFFIT <br />TYPICAL FLAT EAVE w/ CABLES: <br />EPDM RUBBER MEMBRANE (EXTEND MEMBRANE <br />12"-18" UP/DN ABUDDING WALLS/ROOFS) <br />3/4" PLYWOOD SHEATHING w/ WEDGE BLOCK <br />2X4 LOOKOUTS @ 24" O.C. <br />BEAM FLUSHED PER MFG. SPEC. <br />5/4" x 8" COMPOSITE FASICA w/ METAL DRIP EDGE <br />3/4" BACKING <br />4/4" x 10" COMPOSITE FASCIA <br />15-1/8" x 1-1/4" RIM BOARD SUB FASCIA <br />2X4 BLOCKING <br />COMPOSITE VENTED SOFFITS <br />FLOOR TRUSSES <br />PER PLAN <br />1' - 6 3/4"12" <br />2X4 LOOKOUTS <br />2X4 <br />LOOKOUTS 16 7/8"METAL DRIP EDGE <br />5/4" x 8" COMP. FASCIA <br />3/4" BACKING <br />4/4" x 12" COMP. FASCIA <br />16-7/8" x 1-1/4" RIM <br />BOARD SUB FASCIA <br />EPDM RUBBER MEMBRANE3/4" PLYWOOD SHEATHING @ 1/4" SLOPE MIN.Energy Heel11 3/8"COMPOSITE <br />VENTED <br />SOFFITS <br />FLAT EAVE @ BONUS ROOM: <br />EPDM RUBBER MEMBRANE (EXTEND MEMBRANE <br />12"-18" UP/DN ABUDDING WALLS/ROOFS) <br />3/4" PLYWOOD SHEATHING w/ WEDGE BLOCK <br />2X4 LOOKOUTS @ 24" O.C. <br />5/4" x 8" COMPOSITE FASICA w/ METAL DRIP EDGE <br />3/4" BACKING <br />4/4" x 12" COMPOSITE FASCIA <br />16-7/8" x 1-1/4" RIM BOARD SUB FASCIA <br />COMPOSITE VENTED SOFFITS <br />DRAWN BY <br />DESCRIPTION PROJECT # <br />PROJECT ISSUE <br />RE-ISSUE <br />BUILDER a18476 KENRICK AVE. SUITE #202 <br />LAKEVILLE, MN 55044 <br />TEL: 952.428.8200 <br />EM: Dave@DavidCharlezDesigns.com <br />D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S <br />Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of <br />the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, <br />quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction <br />issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or <br />other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer <br />and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size <br />are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be <br />flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific <br />manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with <br />local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult <br />builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design <br />retains rights to all plans and detail shown. <br />2/16/2023 3:37:45 PM 12Cross Sections MISC - Beduhn - CD <br />Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM <br />1340 Vine Place <br />Orono, MN <br /> 1/2" = 1'-0" <br />1Typical Wall Section 1 <br /> 1" = 1'-0" <br />2Detail - Typical Eave <br /> 1/2" = 1'-0" <br />3Typical Wall Section 2 <br /> 1 1/2" = 1'-0" <br />5 Detail - Typical Eave w/ Hangers <br /> 1 1/2" = 1'-0" <br />6 Detail - Flat Eave @ Bonus Rm <br />IMPORTANT REMODEL NOTE: <br />VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY <br />FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR <br />STARTING CONSTRUCTION <br />ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING <br />ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING <br />VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, <br />FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR <br />STARTING CONSTRUCTION <br />FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR <br />STARTING CONSTRUCTION <br />ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL <br />BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS <br />STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO <br />CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO <br />THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS <br />REVISION SCHEDULE <br />Number Date Issued by <br />CDRev1 1.18.2023 GM <br />CDRev2 1.24.2023 JCB <br />CDRev3 2.2.2023 GM <br />CDRev4 2.16.2023 LMC