UN I V E RS I T Y Septic System ,�lanagement Plan <br /> for Above Grade Systems <br /> OF MINNESOTA � �� � <br /> �,���, <br /> _ �, <br /> Professio�al Management Tasks <br /> lhese are the operation and maintenance activities tha! a pumper/maintainer performs to help ensure <br /> long-term perfor»sance of your system. Professionals should refer to the O/M Manual for detailed <br /> checklists for tanks,pumps, alarms and other components. Call 800-322-8642 for more details. <br /> ❑ Written record provided to homeowner after each visit. <br /> Plumbing/Source of Wastewater <br /> ❑ Review the Water Use Appliance Chart on Page 5 with homeowner. Discuss any changes in <br /> water use and the impact those changes may have on the septic system. <br /> ❑ Review water usage rates(if available)with homeowner. <br /> Septic Tank/Pump Tanks <br /> o Manhole lid. A riser is recommended if the lid is not accessiUle from the ground surface. Insulate <br /> the riser cover for frost protection. <br /> ❑ Liquid level. Check to make sure the tank is not leaking. The liquid level should be level with the <br /> bottom of the outlet pipe. (If the water level is below the bottom of the outlet pipe, the tank may <br /> not be watertight. If the water level is higher than the bottom of the outlet pipe of the tank, the <br /> effluent screen may need cleaning, or there may be ponding in the drainfield.) <br /> ❑ Inspection pipes. Replace damaged caps. <br /> o Baf�les. Check to make sure they are in place and attached, and that inlet/outlet baffles are clear <br /> of buildup or obstructions. <br /> ❑ Effluent screen. Check to make sure it is in place; clean per manufacturer recommendation. <br /> Recommend retrofitted installation if one is not present. <br /> ❑ Alarm. Verify that the alarm works. <br /> ❑ Sct�m and sludge. Measure scum and sludge in each compartment of each septic and pump tank, <br /> pump if needed. <br /> Pump <br /> ❑ Pump and controls. Check to make sure the pump and controls are operating correctly. <br /> ❑ Pz�mp��ault. Check to make sure it is in place;clean per manufacturer recommendations. <br /> ❑ Alarm. Verify that the alarm works. <br /> ❑ Drainback. Check to make sure it is operating properly. <br /> ❑ F.vent cozrnter or run time. Check to see if there is an event counter ar nin time log for the pump. <br /> If there is one, calculate the water usage rate and compare to the anticipated average daily flow <br /> listed on Page 2. <br /> Soil Treatment Area <br /> o Inspeclion pipes.Check to make sure they are properly capped. Replace caps that are damaged. <br /> ❑ Surfacing of effluent. Check for surfaced ettluent or other signs of problems. <br /> ❑ Lateral flushing. Check lateral distribution; if cleanouts exist, flush and clean as needed. <br /> u Ponding. Check for ponding. Excessive ponding in at-grade and mound beds indicates <br /> problems. <br /> All other components—inspect as listed here: <br /> - 4 - <br /> �oios <br />