My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993-08-09 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4245 Bayside Road - 06-117-23-13-0004 - New PID
>
4245 Bayside Rd - PID: 06-117-23-13-0001 - Old PID
>
Septic
>
1993-08-09 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:19 PM
Creation date
5/8/2023 4:18:14 PM
Metadata
Fields
Template:
x Address Old
House Number
4245
Street Name
Bayside
Street Type
Road
Address
4245 Bayside Rd
Document Type
Septic
PIN
0611723130004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />CITY OF ORONO <br />Municipal Offices <br />Post Office Box 66 <br />Crystal Bay, 00 55323-0066 <br />Owner: �l-�— I)A L Address: <br />i'ermit /'s: Dates: <br />Contractors: <br />ON—SITE SEWAGE T>REATfrIRNT <br />INSPECTION REPORT <br />City ordinance number TDO requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br />The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br />checked below. <br />(This is W an existing system I I new construction) <br />-3)- <br />"CODE SYSTEM" -A system which meets all the location, design, and construction standards of the current City <br />Codes, and which is operating satisfactorily by treating and disposinn of the entire current sewage input <br />without discharp!ng any pollutants into ground or surface waters. <br />"CONFORMING SYSTEMI-A system which does not meet all the location, design, and construction standards of the <br />current City Cares, but was installed according to the code in effect at the time of installation, and which <br />is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br />any pollutants into ground or surface waters. <br />"NON -CONFORMING SYSTEN"-A prohibited system; a system located within a designated TDO -year flordplain; any <br />system which may or may not meet all the location, design, and construction standards of the current City <br />Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br />between the distribution device and the limiting soil characteristics. <br />(The limitsn? soil characteristic P4 has or I I has not been identified at this time. If the limiting soil <br />characteristic has not been identified, this classifir.ation may be subject to revision.) <br />Tank inspection Indicates: <br />S Pupout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br />7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br />a System is dticharging to the surface. Tanks must be pupped out within GB hours to eliminate surface discharge. <br />9 Inspection risers missing -tanks could not be inspected. Inspection risers (G" dia. pipe) must be installed in each <br />tank at next pur%mt. If tanks have not been pumped out within the last three years, they should be pumped <br />out now. <br />10 Inspection pipe is located directly over tank baffle (does not give accurate measureme-t of solids accumulation). <br />If tanks have not been purped out within the last three years, they should be pumped out tww. <br />DRAINFIE(D CONDITION (11.14): <br />O lfield inspection indicates: <br />(If!1/ Drainfield Is dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />ti Drainfield extent and condition unknown. <br />LIMITING SITE FACTORS (s'ope.setbacks,etc.): <br />POTENTIAL FOR SYSTEM FAILURE (depends on -nils-water tabte.etc,): <br />nspector <br />Note: in the event that this inspection rep.rt is used to satisfy the requirements for a mortgage or other transfer of <br />property, be advised that thi• report does not guarantee or certify that an existing system will continue to function <br />properly, but is merely an opinion of the adequacy of the system oder current conditions cased on the available <br />information. <br />this report must be kept on the prcaises with the system location and purging records. <br />WHITE COPY Inspeclors HM YELLOW COPY Homeowner <br />