1988-10-05 Soil Compaction Test Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
4165 Bayside Road - 06-117-23-14-0019
>
Septic
>
1988-10-05 Soil Compaction Test Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:43 PM
Creation date
5/5/2023 3:56:25 PM
Metadata
Fields
Template:
x Address Old
House Number
4165
Street Name
Bayside
Street Type
Road
Address
4165 Bayside Rd
Document Type
Septic
PIN
0611723140019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Jame:: Alt <br />May 19, 1988 <br />Page 2 <br />The measured percolation rates are consistent with the texture of <br />the soil materials in which the percolation tests were run. <br />Septic system drainfields require at least three (3.0) feet eleva- <br />tion difference between the bottom of the filter rock and ground <br />water or indication of periodic soil satura':ion such as soil mott- <br />ling to perform properly. To meet this requirement, a mound septic <br />system is recommended for soil conditions on this lot. <br />The mound is designed to serve a four bedroom house with a whirl- <br />pool bath. Design sewage flow is 600 gallons per day for the <br />house. A sewage flow of 75 gallons per day is added for the <br />whirlpool bath. Total design -ewage flow is 675 square feet. With <br />a design infiltration rate of 1.2 gallons effluent per square foot <br />per day, the required rock bed area of the mound is 562.5 square <br />feet. <br />675 gal/day - 1.2 gal/ft 2/day - 562.5 ft <br />A rock bed 10.0 feet wide by 56.0 feet long provides the needed <br />area. A minimum of one (1.01) foot of medium sand should be con- <br />structed below the rock bed of the mound. <br />The pressure distribution system of the mound consists of Schedule <br />40 PVC plastic pipe. The supply pipe should slope back towards the <br />Pumping chamber so that it drains after the mourd is dosed. The <br />laterals are 1.5 inch inside diameter pipes. The laterals should <br />have 1/4 inch diameter holes drilled at a spacing of 7.0 feet. The <br />laterals should be assembled to the manifold so that the holes <br />point downwards into the rock bed. The C stal ends of the laterals <br />should be drilled horizontally in the end cap near the crown of the <br />pipe to facilitate air venting. <br />A submersible effluent pump capable of delivering at least 42 <br />gallons per minute against a total dynamic head of at least 22.7 <br />feet should be selected. Headlosses are calculated as follows: <br />1. Vertical headloss of 12.2 feet between pump di.:harge (approx. <br />elev. 87.0) and manifold (approx. elev. 99.2) <br />2. Friction loss of 4.1 feet in 14C feet of supply pipe (2.9 feet <br />per 100 feet 2.0 inch inch I.D. plastic pipe at 42 gpm flow), <br />3. Friction loss of 1.0 feet in piee fittings equal to 25 percent <br />of friction loss in supply pipe. <br />4. Five feet (5.01) to account for losses in distribution network. <br />L <br />J <br />