My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-29-2021 Septic Maintenance Report
Orono
>
Property Files
>
Street Address
>
L
>
Lyman Avenue
>
1190 Lyman Avenue - 35-118-23-43-0034
>
Septic
>
06-29-2021 Septic Maintenance Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:44 PM
Creation date
4/25/2023 2:15:40 PM
Metadata
Fields
Template:
x Address Old
House Number
1190
Street Name
Lyman
Street Type
Avenue
Address
1190 Lyman Avenue
Document Type
Septic
PIN
3511823430034
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Septic Check <br /> ► <br /> 6074 Keystone Rd p t D'• 35 l l Q p 1343 O03 4 320-983.2447 <br /> Milaca,MN 56353 Fax:320-983-2151 <br /> e-PROPERTY INFORMATION <br /> Brian Palmer <br /> Location:1190 Lyman Ave <br /> Orono <br /> Tax ID:35-118-23-43-0 <br /> Mail re: Brian Palmer <br /> 1190 Lyman Ave Use:Residential,Single Family <br /> Orono,MN System Design Flow:600 <br /> 55391 GENERAL SYSTEM TYPE:STAND Res 1 NO TEST <br /> Fold , ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold <br /> Here Here <br /> Inspected:06/29/2021 - Inspection Type:ROUTINE - Correction Status:No corrections needed <br /> Company: Work Performed By: Submitted 07/01/2021 by: <br /> Septic Check Michael Pederson Heather Johnson <br /> COMMENTS&GENERAL INSPECTION NOTES <br /> No Deficiencies Noted <br /> Everything looks great and is working properly. Have a great day! <br /> GENERAL SITE&SYSTEM CONDITIONS <br /> The General Site and System Conditions were: Fully Inspected <br /> Components accessible for service: YES <br /> All required service performed(if no-specify omitted inspection items in notes): YES <br /> Surfacing effluent from any component(including mound seepage): NO <br /> Components appear to be watertight-no visual leaks: YES <br /> Improper encroachment(structures/impervious surfaces);cover,or settling problems observed: NO <br /> ONSITE SEWAGE SYSTEM INSPECTION DETAIL <br /> TANK:Septic Tank-1 Compartment,Manufacturer= Local Manufacturer-Concrete Septic Tank#1-1,500 Gallon <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> This component was: Fully Inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N/A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 1 <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 4 <br /> Pumping recommended: NO <br /> Ift Wt; tatrI IEN •ri••l fl'f M117101471l'1=1111:1"1111rr!�- 110741= 't11• tfO :frke!"iNdelrlef I•► <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> This component was: Fully Inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N/A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 0 <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 0 <br /> Pumping recommended: NO <br /> TANK:Pump Tank,Manufacturer= Local Manufacturer-Concrete Pump Tank-1000 Gallons <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> 'This component was: Fully Inspected <br /> Compartment 1 Scum accumulation(Inches,if other specify): fl <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 2 <br /> Pumping recommended: NO <br /> Pump:Effluent Pump Biotube Pump Vault <br /> Manufacturer:Orenco <br /> This component was: Fully Inspected <br /> Controls functioning: YES <br /> Tested gallons per minute flow: NA <br /> ReportlD:975869 View inspection reports online at www.onlinerme.com Page 1 of 2 <br />