Laserfiche WebLink
Septic Check <br /> ► <br /> 6074 Keystone Rd p t D'• 35 l l Q p 1343 O03 4 320-983.2447 <br /> Milaca,MN 56353 Fax:320-983-2151 <br /> e-PROPERTY INFORMATION <br /> Brian Palmer <br /> Location:1190 Lyman Ave <br /> Orono <br /> Tax ID:35-118-23-43-0 <br /> Mail re: Brian Palmer <br /> 1190 Lyman Ave Use:Residential,Single Family <br /> Orono,MN System Design Flow:600 <br /> 55391 GENERAL SYSTEM TYPE:STAND Res 1 NO TEST <br /> Fold , ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold <br /> Here Here <br /> Inspected:06/29/2021 - Inspection Type:ROUTINE - Correction Status:No corrections needed <br /> Company: Work Performed By: Submitted 07/01/2021 by: <br /> Septic Check Michael Pederson Heather Johnson <br /> COMMENTS&GENERAL INSPECTION NOTES <br /> No Deficiencies Noted <br /> Everything looks great and is working properly. Have a great day! <br /> GENERAL SITE&SYSTEM CONDITIONS <br /> The General Site and System Conditions were: Fully Inspected <br /> Components accessible for service: YES <br /> All required service performed(if no-specify omitted inspection items in notes): YES <br /> Surfacing effluent from any component(including mound seepage): NO <br /> Components appear to be watertight-no visual leaks: YES <br /> Improper encroachment(structures/impervious surfaces);cover,or settling problems observed: NO <br /> ONSITE SEWAGE SYSTEM INSPECTION DETAIL <br /> TANK:Septic Tank-1 Compartment,Manufacturer= Local Manufacturer-Concrete Septic Tank#1-1,500 Gallon <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> This component was: Fully Inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N/A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 1 <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 4 <br /> Pumping recommended: NO <br /> Ift Wt; tatrI IEN •ri••l fl'f M117101471l'1=1111:1"1111rr!�- 110741= 't11• tfO :frke!"iNdelrlef I•► <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> This component was: Fully Inspected <br /> Effluent level within operational limits(if NO explain in comments): YES <br /> All required baffles in place(N/A=No baffles required): YES <br /> Compartment 1 Scum accumulation(Inches,if other specify): 0 <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 0 <br /> Pumping recommended: NO <br /> TANK:Pump Tank,Manufacturer= Local Manufacturer-Concrete Pump Tank-1000 Gallons <br /> Manufacturer: Local Manufacturer Model:Concrete <br /> 'This component was: Fully Inspected <br /> Compartment 1 Scum accumulation(Inches,if other specify): fl <br /> Compartment 1 Sludge accumulation(Inches,if other specify): 2 <br /> Pumping recommended: NO <br /> Pump:Effluent Pump Biotube Pump Vault <br /> Manufacturer:Orenco <br /> This component was: Fully Inspected <br /> Controls functioning: YES <br /> Tested gallons per minute flow: NA <br /> ReportlD:975869 View inspection reports online at www.onlinerme.com Page 1 of 2 <br />