My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SE22-000025 Design with markups
Orono
>
Property Files
>
Street Address
>
D
>
Deer Run Trail
>
2925 Deer Run Trail - 04-117-23-24-0011
>
Septic
>
SE22-000025 Design with markups
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:10:49 PM
Creation date
4/20/2023 8:15:34 AM
Metadata
Fields
Template:
x Address Old
House Number
2925
Street Name
Deer Run
Street Type
Trail
Address
2925 Deer Run Tr
Document Type
Septic
PIN
0411723240011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: D8AA32DD-94F0-4A26-ACCF-EFE01 D862864 <br />Installer Summary <br />2500 gallon Septic tank (minimum) Tank options: none <br />1250 gallon Dose tank (minimum) at 26.00 gpi <br />47 GPM @ 17 ft. of head, Pump required <br />7.9 inch swing on Demand float which translates to roughly 5.0 inches of float tether length <br />if time dosing is required - 4.4 minutes ON time &t hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or LjUinches to "timer ON" float <br />23 inches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed <br />105 ft. of =inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />24 inch, or 2.0 ft. Sand Lift Mound <br />10.0 ft. wide by 62.5 ft. long Rock bed <br />3 laterals 2.00 inch diameter 60.5 ft. long =ft. lateral spacing <br />114" inch perfs 3.0 ft. perforation spacing <br />F—NO-1 Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio13 ft. upslope berm <br />4:1 sideslope 18 ft, sideslope berms <br />4:1 downslope 23 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope berm F13 .I 1� i- Downslope berri 23 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />2.0 11 Clean sal)d lift <br />Depth Lrj Linr.:i ii n:, ~ <br />Urni1.1P,ii, C.O?ld f1+1i1 - -- -• - -- -- - -- -- <br />Absorption Width 1 27.0- <br />Note: <br />For 0 to 1% stopes, Absorptfbn Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorptfon Wfdth is measured downhill from the upslope edge of the Bed! <br />Rock Bed: 28.0 yd3 or *1.4= 39 ton <br />Mound Sand: 268 yd3 or"1.4= 375 ton <br />Loamy Gap: 89 yd3 or "1.4= 125 ton <br />Topsoil: 101 yd or "1.4= 141 ton <br />9 inches under pipe <br />calculation based on 3:114:1 slope from top of rockbei <br />6" deep <br />6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.