My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1984-09-28 Septic System Approval
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road North
>
900 Brown Road North - 27-118-23-43-0023
>
Septic
>
1984-09-28 Septic System Approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:46 PM
Creation date
3/27/2023 3:53:19 PM
Metadata
Fields
Template:
x Address Old
House Number
900
Street Name
Brown
Street Type
Road
Street Direction
North
Address
900 Brown Road North
Document Type
Septic
PIN
2711823430023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E11P <br />ORTANT - !tOME:OWNER AND BUILDER READ AND UNDERSTAND TRIS APPROVAL <br />PRIOR TO STARTLVV YANY WORKor OON THE SITE !!!!!! <br />Nps) p SEPTIC SYSTE:'l APPROVAL <br />Ego <br />LOCATION 900 North Brown Road <br />GENERAL CONTRACTOR Eiden Constr. Inc. <br />SEPTIC CONTRACTOR <br />OWNER Mark and Maric Robbins <br />APPROVED <br />XXAPPROVED: 'TOTE: CHANGES BELOW <br />CO!VIENTS This lot is extremely limited as a building site <br />due to the location of 2 creeks with steep banks. Orono Code <br />requires that septic sys emrain ie 'sT locatea at reast <br />r"L-+'g'I'd streams If-aving only two <br />acceptable sites for drainfield, the primary site located <br />directly east of the proposed house, and the alternate site to <br />the southwest. 0 1 sites must Be preserven for use as as <br />nr;iginnI :inrl ruLurr. rlr,%infinlrl Thi,; is the only way the City <br />can allow this lot as a buildable site. <br />The proposed design requires a curtain drain located 10-15' <br />away roe e Uoper trenche :)- ear the h=e <br />to eliminate a L.,Lintial high water table problem. A surface <br />DATE APPROVED -I-C',{ �l/ BY: �" • -- <br />water diversion swail above the system would also be prudent to <br />reduce drainage over the drainfield. <br />Because the trenches can be no more than 18" deep into the <br />original soil, and because of the limited area available due to <br />sethack requirements, the final house elevation may dictate that <br />a pump be used in the system. If this turns out to be the case, <br />the preferred method would be to pump the basement only and <br />gravity flow the upper floors. Presuming a basement pump is <br />needed, the original system should be kept as far uphill as <br />possible to preserve the lower area for future use. <br />The well must to located at least 75' from either drainfield <br />site, hence the acceptable well locations fall in a small area <br />at the nortwest corner of the lot. Any water line under the <br />driveway should be placed a minimum of 7' dce with 2" of styro- <br />foam insulation to eliminate potential freezing problems. <br />~KEEP ALL TRAFFIC, FILL, GRADING, ETC. OFF OF DRAINFIELD SITES !!!j <br />
The URL can be used to link to this page
Your browser does not support the video tag.