Laserfiche WebLink
Residential Plans Examiner Review Form <br />Tor <br />HVAC System Design (Loads, Equipment, Ducts) <br />Long Lake, MN <br />Header Information <br />Form <br />RIPER 1 <br />15 Mar 09 <br />Contractor Geothermal Concept <br />REQUIRED ATTACHMENTS <br />Manual J1 Form (and supporting worksheets): <br />ATTACHED <br />Yes [ No <br />Adam Anderson <br />or MJ1AE Form' (and supporting worksheets): <br />Yes No <br />Mechanical license: m�a�.- <br />OEM performance data (heating, cooling, blower): <br />Yes Ej No JR <br />Building plan #: 3/31/2021 <br />Manual D Friction Rate Worksheet: <br />Yes El No lr <br />No <br />Duct distribution sketch: <br />Yes (� <br />Home address (Street or Lot#, Block, Subdivision): <br />275 Market St, Entire House <br />HVAC LOAD CALCULATION (IRC M1401.3) <br />Design Conditions <br />Building Construction Information <br />Winter Design Conditions <br />Building <br />Front Door faces Southeast <br />Outdoor temperature: -26 <br />p <br />'F Orientation: <br />NDMA East, West, SWh, Northeast, NwtwveA Southeast So *Vffl_St <br />Indoortemperature: 70 <br />°F <br />0 <br />Total heat loss: 158040 <br />Btuh Number of bedrooms: <br />Conditioned floor area: 4865 ftz <br />Summer Design Conditions <br />Number of occupants: 8 <br />Outdoor temperature: 96 <br />°F <br />Indoor temperature: 72 <br />°F Windows <br />Roos <br />Grains difference: 58 gr/lb@50%RH <br />Eave overhang depth: 0 ft <br />Sensible heat gain: 82044 <br />Btuh IntemaI shade: none <br />g"mis' drams' ele" <br />Eave <br />Depth <br />Wlndow <br />Latent heat gain: 2389 <br />Btuh <br />0 <br />Total heat gain: 84434 <br />Btuh Number of skylights: <br />HVAC EQUIPMENT SELECTION (IRC <br />41 <br />Heating Equipment Data <br />Cooling Equipment Data Blower Data <br />EUuipment type: GSHP <br />Equ',=pnt typpe: GSHP Heating cfm: <br />4581 <br />rmce,Heatpimp,Boi�er,e6c. <br />AirC.onririaner,iieatPump,etc- Cooling cfm: <br />45581 <br />Model: <br />Model: StFtpra��gn <br />d.)stascpress� <br />+ airlim <br />Heating outputcapacit�: 0 Btuh <br />Total cooling capacity: 0 Btuh <br />Heatp—ps-capaciryat. rdesignoutdoorcorr[tons <br />Sensible cooling capacity: 0 Btuh <br />Aux. heating output capacity: 0 Btuh <br />Latent cooling capacity: 0 Btuh <br />HVAC DUCT DISTRIBUTION SYSTEM <br />f .1 <br />Design airflow: 4581 cfm <br />Longest supply duct: 0 ft Duct Materials Used <br />Equipment design ESP: 0 in H2O <br />Longest return duct: 0 ft Trunk duct: <br />Total device pressure losses: Q in H2O <br />Total effective length (TEL): 0 ft <br />0 in1100ft Branch duct: <br />Sheet metal <br />Available static pressure (ASP): 0 in H2O <br />Friction rate: <br />Riction Rate = ASP a (rELx 100) <br />Contractor's printed name: .AAAV& S <br />Contractor's signature: <br />Home qualifies for MJ1AE Form based on Abridged Edition Checklist <br />wrightsoft` Right-SuiteDUniversal201818.0.32RSU12703 <br />Date: (, _.Z-Zoz I <br />