Laserfiche WebLink
7110FT -IY Project Summary <br />I> oncepC;3 Entire Nouse <br />Geothermal Concept <br />P.O. Box 444, Clearwater, MN 55320 Phone: 612 481.4020 Email: adam@geothermalconcept mm Web: vohW.ge0ftr1na1C0Rcept.00m <br />Promect Information <br />For: Reuter Residence, Hage Homes <br />275 Market St, Minneapolis, MN 55405 <br />Phone: 763.286.3369 <br />Web: hagehomes.com <br />Notes: <br />Design Information <br />Weather: St Cloud Regional AP, MN, US <br />Job: 60220211 <br />Date: Jun 02, 2021 <br />By: Adam Anderson <br />Plan: 3131/2021 <br />Winter Design Conditions <br />Summer Design Conditions <br />Outside db -26 <br />OF <br />Outside db <br />96 <br />OF <br />Inside db 70 <br />OF <br />Inside db <br />72 <br />°F <br />Design TD 96 <br />OF <br />Design TD <br />24 <br />OF <br />Daily range <br />M <br />Relative humidity <br />50 <br />% <br />Moisture difference <br />58 <br />grAb <br />Heating Summary <br />Sensible Cooling Equipment <br />Load <br />Sizing <br />Structure 127731 <br />Btuh <br />Structure <br />82537 <br />Btuh <br />Ducts 0 <br />Btuh <br />Ducts <br />0 <br />Btuh <br />Central vent (0 cfm) 0 <br />Btuh <br />Central vent (0 cfm) <br />0 <br />Btuh <br />(none) <br />(none) <br />Humidification 0 <br />Btuh <br />Blower <br />0 <br />Btuh <br />Piping 30309 <br />Btuh <br />Equipment load 158040 <br />Btuh <br />Use manufacturer's data <br />n <br />Ratelswin multi <br />1.01 <br />Infiltration <br />Equipmensensibleload <br />83032 <br />Btuh <br />Method Simplified <br />Latent Cooling Equipment Load Sizing <br />Construction quality( <br />T1 <br />Fireplaces <br />2 (Tight) <br />Structure <br />2404 <br />Btuh <br />Ducts <br />0 <br />Btuh <br />Central vent (0 cfm) <br />0 <br />Btuh <br />Heating <br />Cooling <br />(none) <br />2404 <br />Btuh <br />Area (ftp) 4865 <br />4865 <br />Equipment latent load <br />Volume (ftp) 25505 <br />25505 <br />Air chan esrhour D.12 <br />0.05 <br />21 <br />Equipment Total Load (Sen+Lat) <br />Req. total 0.70 SHR <br />85435 <br />9.9 <br />Btuh <br />ton <br />Equiv. AVF (cfm) 50 <br />capacity at <br />Heating Equipment Summary <br />Cooling Equipment Summary <br />Make <br />Make <br />Trade <br />Trade <br />Model <br />Cond <br />AHRI ref <br />Coil <br />AHRI ref <br />Efficiency 0 COP <br />Efficiency <br />0 EER <br />Heating input 0 <br />Btuh <br />Sensible cooling <br />0 <br />Btuh <br />Heating output 0 <br />Btuh <br />Latentcooling <br />0 <br />Btuh <br />Temperature rise 0 <br />OF <br />Total cooling <br />0 <br />Btuh <br />Actual airflow 4581 <br />dim <br />Actual airflow <br />4581 <br />cfm <br />Air flow factor 0.036 <br />cfrWBtuh <br />Air flow factor <br />0.055 <br />cfm/Btuh <br />Static pressure 0 <br />in H2O <br />Static pressure <br />0 <br />in H2O <br />Space thermostat <br />Load sensible heat ratio <br />0.97 <br />Capacity balance point= 0 OF <br />Backup: Bryant <br />Input=0 Btuh, Output=0 Btuh, 80AFUE <br />Calculations approved byACCAto meet all requirements of Manual J 8th Ed. <br />2021-Juz-02 19:03:40 <br />w rightSC3 <br />,— RigK-Suiteglniversal 201818.0.32 RSU12703 Page t <br />ACCA F\Doc=ertAdam\WrighwftHVACWage-Rerder.rrip Calc=MJB Frorli]oortaces:SE <br />