My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-15-1999 Planning Packet
Orono
>
Planning Commission
>
1999
>
03-15-1999 Planning Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2023 2:52:27 PM
Creation date
3/22/2023 2:44:12 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
390
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BONESTROO ROSENE ANDERLIK <br />^ I Bones troo <br />Rosene <br />m Anderlfk & <br />I Associates <br />Engineers & Architects <br />March 15.1999 <br />Elizabeth VanZomeren <br />City Planner/Zoning Administrator <br />City of Orono <br />Post Office Box 66 <br />Crystal Bay. MN 55323 <br />Re; Oronu Middle School <br />File No. 139-2471 <br />©6516361311 03/15/99 11:35 0 :01/02 N0:968 <br />ArVtv/nA tne it A/fnnutt'vr (*>pfOfrt4rnty Ctnploviff <br />Ono O Oonrtfuu. rc • JOSep'^f. An:trriia •'f • M.tr # ri L jm ft • <br />RirhAfdi ru'ncr. Pt •OirnrtR Cool •Rnf.i 'tO Vh.jochi a QuufUuh. PC • <br />RoUarrt W f?Cit*nf. Pt fnh Sut^n M C f A Srr*. n c ’ f^ti.'r <br />ASSOCfiHe Hou^imJ A SAnrerC PC •«i*ifhA ltf,nu n Of • Putiirft R PfeffCfiiJ. P| • <br />Picna^O W fnitrr. Pf • O.^viu O Lcihoi.-i ft • * •rn»\ri aia • M.i»» A ha*sica Ft • <br />Mithatl T ffputmpnn. Pf • K ririu pc • K«nncfh r Ah'H ruin bf , n P£ , <br />iCliJrivy P MWII'Aiviion fk . I S • &ol»»*rf I* • Agnct M (Itnrj • Mm P P.n. Pf • <br />AiMfiPick Schmidt. PC <br />Si RoiKetttr. WuiniAf v» MamiI MN • Alt ^ iti <br />Wpbiitt. wwwROhfltfno f om <br />Dear Liz: <br />We have reviewed the preliminary plans for the proposed Orono Middle School. The site Is located cast of <br />Old Crystal Bay Road, south of County Road 6 and north of Orono City Hall in the southeast quarter of <br />Section 28. Wc have the following comments In regards to engineering matters. <br />1. Accent: The proposed access locations appear to be acceptable. A pedestrian crossing should be shown <br />at the south access. This location is near the crest of the hill and provide.! for maximum sight distances. <br />.Signing, striping and lighting plans for this crossing should be submitted for review, ivde.sirian cro.sslngs <br />at the northerly access should be discouraged. Geotechnical recommendations and pavement design <br />should be provided for our review. <br />2. Sanitary Sewer: The plans show the invert elevation of the existing MH 1 at 101.3.3. The proposed <br />upper and lower floor elevation.! for the school are 1036.33 and 1023.00 respectively. The sewer service <br />from the school would flow into MH 2, which has a proposed invert of 1031 .1 8. Tlii.s design would allow <br />for gravity service to only the upper floor of the school. The dc-sign would provide a 3.1 2-foot build for <br />MH 2. The cxi.sting MH 1 invert is low enough to allow for gnivity service to both floors and provide <br />adequate cover at MH 2 so that insulation wouldn’t be necessary and freezing wouldn’t be a concern. It <br />is unclear why the propo.sed dc.sign docs not provide for gravity service to the entire building. The sanitary <br />sewer schedule incorrectly identifies MH 2 a.s MH 1 . The sanitary sewer .schedule should be revised to <br />agree with the plans. All sanitary and storm sewer manholes and catch basins shall have an exterior <br />sealing sleeve as manufactured by Infl-Shield or an approved equal. The City standard solid casting for <br />sanitary and storm manholes is 1642B, the plans Incorrectly show the casting number as R-1733. A note <br />should be included in the plans specifying that sanitary sewer have 18 inches of clearance below the water <br />main at all sonitary sewer / water main crossings. The connection to the existing sanitary manhole shall <br />be core drilled and u rubber boot in.stalled. Insulation should be provided for all sanitary sewer with less <br />than 6 feet of cover. <br />3. Water Main: Will the water main crossing Old Crystal Bay Road be jacked or ojsen cut? The nacthod of <br />Installation should be specified. If the ro.^dway is open cut a street restoration detail and traffic control <br />plan should be included in the plan set. All 1 2*inch volvcs should be buiierfly vuhes and o dciaii included <br />in the plan set. One of the hydrants on the east side of the building should Iv moved to eliminate an <br />approximate 30-foot gap In coverage near the center of the building. All hydr.inis should l5c u minimum <br />of 50 feet away from the cxlcricr wail of the building. <br />4. Storm Sewer: We recommend that catch basins be provided at all four access l«x:ations. All stonn sewer <br />should be reinforced concrete pipe. Wc recommend that the minimum pi|)e size for u storm sewer <br />2335 Weit Highway 36 • St. Paul. MN 55113 • 651*636*4600 ■ Fax; 651*636*13ll
The URL can be used to link to this page
Your browser does not support the video tag.