VENTILATION Rt'+l UIREMENTS <br />TABLE 11404,52 <br />NUMBER OF BEDROOMS <br />9.. Conditioned space includes the basement and conditioned crawl spares. <br />2, If conditioned space exceeds 6000,5q. ft. or there aro more than 8 bedrooms, use Equation 8403.5.2 <br />R4rJ3.5.2 Total Ventilation xate. '-7:?-�� > az-� J-av(C((, ;- <br />The mechanical ventilation system shall rovide sufficient outdoor alr to equal the total ventilation rate average <br />for each 9.- hour.period In accordance with Table 84.03.5.2, or Equation 403.5.2, based on the number of bedrooms and <br />square footago of conditioned space, including the basement and conditioned crawl spaces. <br />For the purposes of7'able R403.5.2 and Section 8403.5.3, the following applies: <br />a. Equation R403.5,2 Total ventilation raise: <br />Total ventilation rate (cfm) G (0.02 x square feet of conditioned space) + (9.5 x (number of bedrooms+:L)) <br />b. Equation 13403.52.9. Continuous ventilation rate, Continuous ventilation rate (efm) = Total ventlatlon rate/2 <br />Amount Total' <br />Amount'Continuous l <br />