Laserfiche WebLink
w 03/16/00 10:11 0 :01/02 NO:7A5 <br />i, |l Bonestroo <br />Rosene <br />Anderlik & <br />Y\ I Associates <br />Engineers & Architects <br />flonrrf';.**, ^Ojcntf ^na ASSOCl^t^i. /nt H Aff<nn.tf$vi» Action i^uju opportunity- tnpfp/0* <br />Otto G 3o»*» tf sf rc • Jcjsepn c Anuerlib flit • M.Vv.o w Surv.iui Pfc # <br />Glenn J» Cook. PE • P^brrt C Scnwnuht. PC • Jcr*y A Bcurdon PE • <br />.tooen w rfnsrrc Pf P Chi*<’J E Turn«» P€ ir>0$ui«nw Cacriin r. PA Urruot Con%ui(i,niS <br />Afinc’^rc '^'"incfOAtf A Sanford. PI. Keicn A. GorUcn PE « Pooeft I7 P»effer|# p£ • <br />.'f fharj j/ fotte' P£ • DavidO Loskouv Pf • .'Jobtrt C Punen aia • M.irk a Hanson PC. • <br />M»cnae« PC • Ted K.Pieul. PE • Kcnnetn P Andrr;on P| • M^rk R Pr^ifi. pg • <br />><orty • Jr.li#4imicn. PC L S • PoOcfC P itoumicfi • Agnei M Pmg • Anan «#».► ScrmiOt PC <br />O^TiCrs 5f Pauf. dorrf j?e» Willmar and $f C<0Ud. MN • M««waukOC. W1 <br />U/tL’i/.*r iwv^’.vhnnr j*rnn rf>m <br />March 16. 2000 <br />Mr. Paul Weinberger <br />Zoning Atlminislraior/PUinncr <br />C!iiy of Oiono <br />Post Ortice Box 66 <br />Cry'i'tal Bay, MN 55323 <br />Rc;Walfred Properticb/Snyders Site <br />File No. 139GEN-2567 <br />Dear Paul <br />Wc have reviewed the preliminary grading and uliliiy plan for the propo.sed Snyders site in Nanirrc TIk site <br />IS located un the cast side of Shadywond Road (CSAH I9> and north of Navarre Lane and Shoreline Drive <br />iC.SAH I .^1 We have the following comments in regards to engineering matters: <br />1.Overall: The scale shown on the plan set I r’=30’) does not agree with the dimensions shown on the <br />drawing (s.aniiary sewer lengths), it appears that the drawing was plotted at some other scale. For this <br />reason we were unable tc> verify such things as piuking lot grades, pipe inverts, pond copocines, etc. Once <br />a revised scalable drawing is submitted we will complete our review. <br />2.Sanitary Sewer: The existing sanitary sewer is shown through the proposed ponding area. The plans <br />show a proposed realignment of the sewer through this area. The revised alignment shows the sewer <br />approximately 7*feet away from an existing water main where 10-feet is the standard. The sewer should <br />he reUwated outside the normal water level (NWL) of the pond. Plans should be submitted to the <br />Department of Health for their approval. The proposed sewer realignment falls outside the property. <br />Additional land or casements will need to be acquired to construct the pond and sanitary sewer. The <br />sanitary sewer should have a minimum of 6-fect of cover or should be insulated. All sanitary and stonn <br />sewer manholes arc required to have un exterior scaling sleeve as manufactured by Infi-Shield or an <br />approved equal Any connections to existing manholes shall be core drilled and a rubber boot installed. <br />All applicable City Standard Details .should be included in the final plan set. <br />3.Grading: We recommend that access and parking lot grades not exceed 4*:?:. The proposed design may <br />be within these parameters but we cannot verify until we gel a scalable plan. The proposed retaining walls <br />are nearly 20-fcct tall in some tocation.s Retaining wall design and details should be provided for review. <br />A two tier wall de.sign may be necessary where wall heights approach 20 feet. Some type of barrier w-ill <br />he necessary above the wall in some locations for safety purposes. <br />Di'iiinagv/Honding: As previously stated, the proposed pond lies outside the property boundaries, Uw <br />applicant should provide details as to liow the pond can be constructed and how it may impact the e.xisiing <br />wetland. The pond should be sized according to NURP standards using a 2.5-inch rainfall over the <br />eontnbuting drainage area. Calculations submitted used a 2*inch rainfall and should be revised. The pond <br />will require an outlet structure capable of providing I-foot of skimming as shown in City Standard Detail <br />STO-8A. The pond should be consirucicd in accv>rdance with City Standard Detail STO-12. Pond and <br />siomi sewer calculations should be revised and resubmitted along with a drainage area map. It is uncle;ir <br />where the propo.sed catcli basin on the north side of the site drains to. Riprap should be provided at all <br />outleb. Slorm sewer should be reinforced concrete pipe. Final plans should show plan and profile views <br />2335 West Highway 36 > St. Paul, MN 55113 • 651-636*4600 > Fax: 651-636-1311 <br />: