Laserfiche WebLink
From: gnelson@ci.oron o.mn.us <br />Sent: 12/01/2022 - 09:30 AM <br />To: mark@riccarhvac.com <br />CC: gnelson@ci.orono.mn.us <br />Subject: Inspection Report Individual <br />CITY OF ORONO <br />2750 KELLEY PARKWAY <br />ORONO, MN 55356 <br />PH: (952) 249-4600 <br />FAX: (952) 249-4616 <br />Inspection Report <br />1855 Concordia Street <br />Permit Number: M22-000369 <br />Site Address: 1855 Concordia Street, Orono, MN 55391 <br />Property JAMES A KELLY <br />Owner: <br />Description: NEW CONST- FURNACE -AC -AIR X -IN FLOOR HEATING RI ONLY 3 PANASONIC <br />BATH FANS <br />Inspection Date: 12/01/2022 <br />Inspection Type: Mechanical - Rough In <br />Inspection Results: Partial Pass <br />Inspection Status: Re -inspection Required <br />1. Nail plates on load bearing walls require 8 nails each side of notch more than 50 percent cut. Lower level. <br />2. 4 inch nail plate below top plate of wall required where gas line is within 1 and 1/2 inches depth. Lower level. <br />Inspection Status: Review Comment <br />1. Gas line air test at 20 lbs. <br />Sincerely, <br />Ate~ <br />Gary Nelson <br />952-242-4442 <br />To schedule your inspections please call: (952) 249-4600 <br />CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! <br />