1978-05-22 Septic System Design & Soil Test Report
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road North
>
744 Brown Road North - 34-118-23-12-0005
>
Septic
>
1978-05-22 Septic System Design & Soil Test Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:53:45 PM
Creation date
3/8/2023 3:58:56 PM
Metadata
Fields
Template:
x Address Old
House Number
744
Street Name
Brown
Street Type
Road
Street Direction
North
Address
744 Brown Road North
Document Type
Septic
PIN
3411823120005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS FOR PROPOSED ON-SITE SEWAGE DISPOSAL SYSTEM <br />CONVENTIONAL SYSTEM <br />LOCATION: Don Roderick, System Design for Tract A, Registered Land <br />Survey No. 1275 Orono, Minnesota, Job No. 11-78-22 <br />DATE: May 31, 1978 <br />I. SEWAGE TANK - TWO 1000 -gallon LIQUID CAPACITY tanks, IN SERIES, <br />manufactured and installed in compliance with the <br />following specifications. See Figure 1 for location. <br />1. MATERIALS <br />A. General <br />All tanks, regardless of material or method of construction shall <br />be: <br />(1) Water tight <br />(2) So designed and constructed as to withstand all lateral earth <br />pressures under saturated soil conditions with the tank empty. <br />(3) So designed and constructed as to withstand a minimum of seven <br />feet of saturated earth cover above the tank top. <br />In addition, the following specifications apply to specific mater- <br />ials as indicated. <br />B. Precast Concrete Tanks <br />(1) Precast concrete tanks shall be constructed of at least a <br />4,000 psi (pounds per square inch) core test, air entrained <br />concrete mix. <br />(2) Precast concrete tanks shall be cured to at least a seven-day <br />strength before installation. <br />C. Fiberglass and Plastic Tanks <br />Fiberglass and plastic tanks shall be designed and constructed to <br />meet the requirements in Section I - a. above. <br />D. Metal Tanks <br />Metal tanks shall have a wall thickness of at least eight gauge <br />corrosion resistant alloys and shall be coated inside and out <br />
The URL can be used to link to this page
Your browser does not support the video tag.