1978-05-22 Septic System Design & Soil Test Report
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road North
>
744 Brown Road North - 34-118-23-12-0005
>
Septic
>
1978-05-22 Septic System Design & Soil Test Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:53:45 PM
Creation date
3/8/2023 3:58:56 PM
Metadata
Fields
Template:
x Address Old
House Number
744
Street Name
Brown
Street Type
Road
Street Direction
North
Address
744 Brown Road North
Document Type
Septic
PIN
3411823120005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A. The LIQUID DEPTH of any septic tank of compartment thereof <br />shall be not less than 30 inches. A liquid depth greater <br />than six and one-half feet shall not be considered in de- <br />termining tank capacity. <br />B. No tank or compartment thereof shall have an inside horizontal <br />dimension less than 24 inches. <br />C. Inlet and outlet connections of the tank thereof shall be sub- <br />merged by means of vented, sanitary tees or baffled. <br />D. The space in the tank between the liquid surface and the top <br />of the inlet and outlet baffles or sanitary tees shall be not <br />less than 20 percent of the total required liquid capacity, <br />except that in horizontal cylindrical tanks this space shall <br />be not less than 15 percent of the total required liquid <br />capacity. <br />E. The inlet baffle or sanitary tee shall extend at least six <br />inches but not more than 20 percent of the total liquid depth <br />below the liquid surface and at least one inch above the crown <br />of the inlet sewer. <br />F. The outlet baffle or sanitary tee and the baffles or sanitary <br />tees between compartments shall extend below the liquid surface <br />a distance equal to 40 percent of the liquid depth except that <br />the penetration of the indicated baffles or sanitary tees for <br />horizontal cylindrical tanks shall be 35 percent of the total <br />liquid depth. They also shall extend above the liquid surface <br />as required in D. above. In no case shall they extend less <br />than six inches above the liquid surface. <br />G. There shall be at least one inch between the underside of the <br />top of the tank and the highest point of the inlet and outlet <br />devices. <br />H. The inlet invert shall be not less than three inches above the <br />outlet invert. <br />I. The inlet and outlet shall be located opposite each other along <br />the axis of maximum dimension. The horizontal distance between <br />the nearest points of the inlet and outlet devices shall be at <br />least four f=et. <br />J. Sanitary tees shall be at least four inches in <br />baffles shall be no less than six inches or no <br />inches measured from the end of the inlet pipe <br />point on the baffle. Outlet baffles shall be <br />ured from beginning of the outlet pipe to the <br />the )affle. <br />- 4 - <br />diameter. Inlet <br />more than 12 <br />to the nearest <br />six inches meas - <br />nearest point on <br />
The URL can be used to link to this page
Your browser does not support the video tag.