1995-09-05 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
670 Big Island - PID: 22-117-23-24-0011 - New PID
>
660 Big Island -PID: 22-117-23-31-0026
>
Septic
>
1995-09-05 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:11:39 PM
Creation date
3/8/2023 11:50:03 AM
Metadata
Fields
Template:
x Address Old
House Number
670
Street Name
Big Island
Address
670 Big Island
Document Type
Septic
PIN
2211723240011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO <br />Municipal offices <br />Post Office Bos 66 <br />Crystal Bay, MN 55323.0066 <br />ON—SITE SEWAGE TREATMIIT <br />INSPECTION REPORT <br />Owner: ,171r\ Address: 9,m1 <br />3�(� <br />Permit P's:lua Dates: Contractors: <br />City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br />Theon -site sewage treatment system at the above address has been inspected and appears to fall into the category <br />checked below. <br />(This is ( ) an existing system X new constrt+;font <br />"CODE SYSTEM" -A system which sleets all the location, design, and construction standards of the current City <br />Codes, and which Is operating satisfactorily by treating and disposing of the entire current sewage input <br />Without discharging any pollutants into ground or surface waters. <br />"CONFORMING SYSTEM" -A system which does not meet sit the location, design, and construction starderds of the <br />current City Codes but was installed according to the code in effect at the time of installation, and which <br />is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br />aarr++yy pollutants Into ground or surface waters. <br />"NON- CONFORMING SYSTEM --A prohibited system; a system located within a designated 100 -year floodplain; any <br />system which may or may not meet all the location, design, and construction standards of the current City <br />Codes and which is failsnp for any reason; and any system with less than 3 feet of unsaturated soil or sand <br />between the distribution device and the limiting soil characteristics. <br />(The limiting soil characteristic has or I ) has not been identified at this time. If the limiting soil <br />characteristic has not been idents i this classification may be sub)ect to revision.) <br />lige inspection indicates: <br />('E9 Pualpout not needed at this time. <br />Solids accumulation in tanks indf ales they should be ptrped out lnis year to help prevent future problem . <br />7 Solids acc uulation in tanks is at a critical level. Tanks should be purged out as soon as possible. <br />B System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br />0 Inspection riters missing -tanks could not be inspected. Inspect.on risers (4" '-a. pipe) must be installed In each <br />tank at next ptampout. If tanks have not been pumped out w;thin the lar., three years, they should be pulped <br />out now. <br />10 Inspection pipe is located d;rectlr over tank baffle (does not give accurate measurement of solids accumulation). <br />tanks If have not been puspe0 out within the last three years, they should be pumped out now. <br />DRAINFIELD CONDITION (11.14): <br />OrisinfieldInspection indicates: <br />11 Grainfield is dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. <br />13 Grainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />immediately. Repairs must be completed within VO days. <br />14 Orainfield extent and condition unknown. <br />LIMITING SITE FACTORS (slooe.setbacks.etc.): Ai'n e <br />POTENTIAL FOR SYSTEM FAILURE (depends m solls.water table.etc.): <br />COMMENTS: <br />of Inspection <br />Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br />property, be advised that this report does not guarantee or certify that an existing system will continue to faction <br />properly but is merely an opinion of the adequacy of the system oder current conditions based on the available <br />informstIor. <br />This report must be kept on the pre.aises with the system locstron and pumping records. <br />WHITE COPY Inspeclors F11e IELLOW COPY Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.