1993-08-13 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
4645 Bayside Road - 06-117-23-22-0009
>
Septic
>
1993-08-13 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:49 PM
Creation date
3/7/2023 10:31:29 AM
Metadata
Fields
Template:
x Address Old
House Number
4645
Street Name
Bayside
Street Type
Road
Address
4645 Bayside Rd
Document Type
Septic
PIN
0611723220009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ONONO <br />Municipal Offices <br />Post Office lox 66 <br />Crystal Bay, MN 55323-0066 <br />ON—SITE SEWAGE TREATNM <br />INSPECTION REPORT <br />Owner: e4— Address: WVS/..[. __n, jf' Kl�!- <br />Permit fm's: IMP_ Dates: — Contractors: <br />City ordinance rxarber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br />Theon -site sewage treatment system at the above address has been inspected and appears to fall into the category <br />checked below. <br />(This is A an existing system I ) new construction) <br />NIR <br />"CODE SYSTEM" -A system which meets all the locrtion, design, and construction standards of the current City <br />Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br />without discharging any pollutants into ground or surface waters. <br />"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction standards of the <br />current City Codes but was installed according to the code in effect at the time of installation, and which <br />is operating satisiacterily by treating and disposing of the entire current sewage input without discharging <br />any pollutants into ground or surface waters. <br />"NON -CONFORMING SYSTEM" -A prohibited system; a system located within a desig weed 100 -year floodplain; any <br />system which may or may not meet all the location, design, and construction standards of the current City <br />Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br />between the distribution device arM the limsi!ing soil characteristics. <br />(The iimitinp soil characteristic I ) has or P4 has not been identified at this time. If the limiting soil <br />characteristic has not been identified, this classification any be subject to revision.) <br />Tank inspection indicates: <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br />I Solids accumulation in tanks is et a critical level. s 0uld be puisped out as soon as possible. <br />E System is discharging to the surface. Tanks must be pumped out within 48 hou-s to eliminate surface discharge. <br />9 Inspection risers missing -tanks could not be inspected. Inspection risers (4" dis. pipe) oust be installed in each <br />© tank at next pumpout. If tanks have not been pooped out within the last three years, they should be pulped <br />out now. <br />Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accu.�lation). <br />If tanks have not been puiiped out within the last three years, they should be pumped out now. <br />DRAINFIELD CONDITION (11.14): 13 <br />Drainfield insction indicates: <br />11 Drainfieldpeis dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. <br />1 Drainfield is saturated and visibly discharging untreated effluent to t.:e surface. Contact the City Inspector <br />inemediately. XtpsHrq must be completed within 90 days. <br />14 Drain ea ent and c <br />LIMITING SITE FACTORS (slom.setbacks.etc.): <br />POTENTIAL FOR SYSTEM FAILURE (depends on sc•ils.water table.etc.): <br />COMMENTS: <br />Date of Inspection S69fic System Inspector <br />Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br />property, be advised that this report does not guarantee or certify that an existing system will continue to function <br />properly, but is merely an opinion of the adequa.y of the systems under current conditions based on the available <br />information. <br />This report mint be kept on the premises with the system lccs!im and pumping records. <br />WHITE COPY Inspector* FIN YELLOW COPY flonwownen <br />
The URL can be used to link to this page
Your browser does not support the video tag.