My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-05-12 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4485 Bayside Road - 06-117-23-21-0003
>
Septic
>
1992-05-12 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:20 PM
Creation date
3/7/2023 10:01:39 AM
Metadata
Fields
Template:
x Address Old
House Number
4485
Street Name
Bayside
Street Type
Road
Address
4485 Bayside Rd
Document Type
Septic
PIN
0611723210003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO <br />Municipal Offires <br />Post Office Dox eL <br />Crystal Day, MN 55323.0066 <br />ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />Owner t FoJa 144//5 Address :yy�S f �..Sde U <br />Permit /' et hOl]E_. Dates: <br />Contractors: — <br />City ordinance rxaIor 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br />The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br />checked below. <br />(This is DQ an existing system I ) new construction) <br />"CODE SYSTEM" -A system which meets all the location, design, and construction standards of the current City <br />Codes, and which Is operating satisfactorily by treating and disposing of the entire current sewage input <br />without discharging any pollutants into ground or surface waters. <br />"COMFORMIMG SYSTEM" -A system which rhes not meet all the location, design, and Lonstruction standards of the <br />current City Codes but was instnlled according to the code in effect at the time of installation, and whist <br />is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br />any pollutants into ground or surface waters. <br />"NOM -CONFORMING SYSTEM" -A prohibited system; a system located within a designated 100 -year floodplain; any <br />system which may or may not meet all the location, design, and construction standards of the current Cit! <br />Codes and which Is failing for any reason; and any system with less than 3 feet of unsaturated @oil or sand <br />between the distribution device and the limiting soil characteristics. <br />(The limitir+q soil characteristic I ) has or has not been identified at this time. If the limiting soil <br />characteristic has not been identified, this asslfication may be subject to revision.) <br />Tank inspection indicates: <br />PUlpout not needed at this time. <br />Solids accwlation in tanks indi Utes they should be pulped out this year to help prevent future problewa <br />Solids accumulation in tanks is ata critical level. Tani should be pulped out as scion as possible. <br />a i;ystem Is discharging to the surface. Tanks must be ptaped out within 46 hours to eliminate surtdce discher9e. <br />9 Inspection risers missing tanks could not be inspected. Inspection risers (6" dia. pipe) must be installed in each <br />tank at next pulpout. If tanks have not been pumped out within the last three years, they should be pumped <br />out now. <br />10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br />If tants have not been pumped out within the last three years, they should be pumped out now. <br />DRAINFIELP CONDITION (11 162: <br />Drainfield Inspection indicates: <br />11 Dralnfield is dry, no surfacing evident. <br />1; Some evidence of surfacing, not critcat yet. <br />Drsinfield Is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />I Repairs war r�+(eted within 90 days. <br />ti OreiniilTW_e�tenteno caw, <br />LIMITING SITE FACTORS (sIope.setbacks, etc.). <br />POTENTIAL FOR SYSTEM FAILURE (depends on soils.waner table.etc.): <br />COHMENTS: <br />Date of Inspection <br />ptic System Tif&ctor <br />Mote: In the evert that this inspection report ii used to satisfy the requirements for a mortgage o� other transfer of <br />property, be advisee that this report does not Guarantee or certify that an exist ng system will continue to function <br />properly, but is merely an opinion of the ad.2uacy oo the sy%tem ider current conditions based on the available <br />Information. <br />This report must be kept on the prc.nlse-. with the sy%tem locst m mid pulping records. <br />WHITE COPY Inspectors File YELLOW COPY Homeowner <br />