Laserfiche WebLink
c -•1M <br />SITE EVAI,UATTON REPORT <br />>uR BERNIE NAMES <br />7-23-83 <br />Cn July 16-19, 1963 two percolation holes were tested and <br />two sc.11 borings taken on tre abcve property according to the <br />provisions of Individual Sewage Treatment Systems Standards <br />(WF'C-40) in order to alleviate the present seeping problem.. <br />The soils encountered were good enough for a standard <br />systeir, to be constructed to the west of the present area. The <br />owner indicated 400 square feet of drainfield was already in, <br />which is probably too small for the present house. If these <br />present trenches are still working this area could be subtracted <br />fror,, the total required. Otherwise, the full amount should be <br />installed in the new area. <br />These new trenches should be placed no deeper than 2 feet <br />deep in the natural soil in order to ma4ntain at least 3 feet of <br />seDeration fro-, the possible high water table. Additional system <br />design information follows. If any other information is needed, <br />Please contact me. <br />Sincerely, <br />DERCOR, INC. <br />Nark S. Gronberg, <br />• <br />