Laserfiche WebLink
ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />On the Vortb Sbore of <br />Lake .ttinne•tonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Ra. <br />Crystal Bay, MN 65323 <br />473-7357 <br />OWNER MAJ t 5, -- ADDHESS 7 V -S S 1�4 105c— 5c- kn&b <br />PHONE _ PERMIT NO'S. /10 DATES --G' Po ` 6, Fi <br />City Ordinance No. 210 requires that each on site sewage treatment system in Orono be inspected on a regular basis <br />he on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked <br />below. <br />❑ <br />t <br />Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears <br />o be operating properly. <br />❑ Does not meet current city standards in some respects relating to design, construction, or location. Appears <br />to be operating properly. <br />❑ Ooes not meet Current city standards in many respects relating to design, construction, or location. Appears <br />to be operating adequately. <br />❑ Does not meet current city standards of design, construction or location, is being overused, or is failing to <br />properly treat and dispose of the current input and is therefore endangering a water supply, if a source of <br />pollution to surface or groundwaters, is creating a safety hazard, or is otherwi,3 creating a public nuisance. <br />Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re <br />quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit <br />before work is started. <br />WORK REQUIRED: <br />❑ Septic tanks must be pumped within 48 hours. <br />Drainfield must be repaired or replaced within 90 days. <br />Inspection riser (4" diem. pipe) must be installed in each tank. <br />❑ Tank inspection indicates maintenance pumpout is nef ded as soon as possible. City ordinance requires that <br />tanks be pumped out every three years. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />❑ Slope <br />❑ Soil <br />❑High water table <br />❑ Lot size <br />[]Lake, wetland, or stream <br />❑Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table, and system condition) <br />❑ Low <br />❑ Medium <br />❑ High <br />System is causing visible <br />surface discharge. <br />Site Capabilities for <br />Future Expansion <br />Adequate <br />Fair <br />❑ Poor <br />❑ Inadequate <br />COMMENTS _ S : �'i'' t / S Se'Il°i Let' /A� C= /[,►� �/�'J'/ I�� Z*K'S`II�-' /s Vf_ A <br />Date of Inspection Septic yste s ctor <br />This report must be kept on the premises with system location and pumping records. <br />WHITE COPY / Inspector's File GOLD COPY / Hom-owner <br />