My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995-08-09 On Site Sewage Treatment Inspection Report
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
4360 Bayside Road - 06-117-23-12-0001
>
Septic
>
1995-08-09 On Site Sewage Treatment Inspection Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:09 PM
Creation date
3/3/2023 11:25:10 AM
Metadata
Fields
Template:
x Address Old
House Number
4360
Street Name
Bayside
Street Type
Road
Address
4360 Bayside Rd
Document Type
Septic
PIN
0611723120001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF 0RONO <br />Muni cipal Offices <br />lost Office box 66 <br />Crystal Bay, !M $5323-0066 <br />���kEeHv¢�G <br />Owner: TQ -s �sor� Address: 4- <br />/:ZL62 <br />Permit 0'6: 4Y32 Dates: 6 ori' b,l Contractors: <br />ON-SITE SEWAGE TREATNiff! <br />INSPECTION REPORT <br />City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br />TMOn-site sewage treatment system at the above aduress has been inspected and appears to fell into the category <br />checked below. <br />(This is L,4 an existing system I I new construct,x ) <br />"CME SYSTEM --A system which rets all the location, design, and constructiw.. standards of the current City <br />Codes, and which Is operating satisfactorily by treating and disposing of the entire current sewage Input <br />without discharging any pollutants into ground or surface waters. <br />"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction stardords of the <br />current City Codes but was Installed according to the code in effect at the time of installation, and which <br />is operating satisiactorfly by treating and disposir; of the entire current sews" input without discharging <br />Or pollutantsinto ground or surface waters. <br />"NOM-COMiORN ING SYSTEM --A prohibited system; a system located within a designated 100 -year floodplain; any <br />sstandards ystem which may or my riot meet all the location, design, and construction staards of the current City <br />Codes and which 1■ fainnp for any reason; and and system with less than 3 feet of unsaturated soil or sand <br />batween the dlstributfen dwica and the limiting soil characteristics. <br />(The limiting soil characteristic E4 has or I I has not been identified at this tiara. If the limiting soil <br />characteristic has not been identified, this classification may be subject to revislon.) <br />TANK CONDITION (5.10): <br />TWt Inspection indicates: <br />(3S� puspout not needed at this time. <br />Solids accusul at ion in tanks indicates they should be pt out this year to help prevent future orobleme. <br />7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br />S System Is discharging to the surface. Tanks must be pumped out within iS hours to eliminate surface discharge <br />g Inspection risers missing -tanks could not be inspected. Inspection risers (i" die. pipe) oust be installed in'each <br />tank at next pumpout. If tarns have not been pumped out within the last three years, they should be pumped <br />out now. <br />10 Inspectionpipe Is located directly over tank baffle (does not ive accurate measurement of solids accumulation). <br />If tanks have not been =Out within the last three yews, they should be pumped out now. <br />DRAINFIELD COMDITION (11.11): LL <br />Dr�)ltf laid l,xcitlon indicates: <br />`IIKV Onfnf Feld fs dry, no surfacing evident. <br />Some evidence of surfacing, not critical yct. <br />13 Grainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />Im w is (y. Repel rs must be completed within t)0 days. <br />to Drainfleld extent andCondit ionunknown. <br />POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): <br />COMMENTS: <br />Date of Inspection Sepitic Sy tem Inspector <br />Note: In the event that this inspection report is used to satisfy the requirementsfor a acirtgsppe or other transfer of <br />property, be advised that this report does not guarantee or certify that an existing system will continue to function <br />properly, but is rarely an opinion of the adequacy of the system under current conditions based on the available <br />information. <br />This report must be kept on the prcAises with the system locstton and pumping records. <br />WMfTE COPY Anspeeiots File YELLOW COPY Non isaimi s, <br />
The URL can be used to link to this page
Your browser does not support the video tag.