My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7315
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2815 Casco Point Road - 20-117-23-32-0011
>
Resolutions
>
Resolution 7315
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:57:48 PM
Creation date
2/24/2023 12:07:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2815
Street Name
Casco Point
Street Type
Road
Address
2815 Casco Point Road
Document Type
Resolutions
PIN
2011723320011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCHIMNOWSKI <br />CRITERIUM` <br />ENGINEERS <br />August 24, 2022 <br />Josh Peterson <br />Valdes Lawn Care & Snow Removal <br />Submitted by email: jpeterson@valdeslawn.com <br />RE: Segmental Retaining Wall Typical Section <br />Project Location: 2815 Casco Point Road, Wayzata, Minnesota <br />Project No. 22-6589 <br />Dear Mr. Peterson: <br />This letter includes important details regarding the attached design typical engineered sections for the <br />timber retaining walls at the above location. This design is based on wall layout information provided by <br />you in an email on August 23, 2022, including: a Certificate of Survey prepared by Gronberg and <br />Associates dated May 18, 2022; measurements of the wall heights and face to face distances; and <br />photos of the existing conditions. <br />The attached typical section should be referenced for construction details. Special note should be made <br />of the wall embedment depth and the tieback/header and deadmen lengths. Refer to local building <br />codes, industry specifications, and American Wood Preservers Association for installation information and <br />details. <br />The design of the wall system assumes the following: <br />• Wall location: Replacement of the existing tiered timber walls in the same configuration <br />• Wall height(s): 7 -feet to 2 -feet as noted on the attached sketch, with minimum face-to-face <br />distance between the walls (maximum exposed heights) <br />Minimum embedment depth = 6" min., or as noted <br />• Soil conditions: Silty/Clayey Sand, friction angle = 30.0 degrees, unit weight of 125.0 Ib/ft3 <br />• Required minimum soil bearing capacity = 1500 psf <br />• Surcharge load at top of walls: Decks as noted <br />• 10:1 maximum slope at top and bottom of walls <br />• Wall Type: 6" Treated Timber <br />• Connections: 3/8" galvanized or treated spikes <br />• Drainage pipe: Required <br />These walls have not been designed for ground water surcharge loads. Direct all surface and <br />groundwater drainage away from the walls. Methods to do so include but are not limited to the following: <br />drainage swale, site grading, retention ponds, etc. Details of water control are left to the wall contractor or <br />the site civil engineer. Please contact Criterium-Schimnowski to provide additional site assessment <br />services if desired. <br />The wall design was performed using the design guidelines presented in timber retaining wall industry <br />guidelines and recommendations. Additional information requested by Criterium-Schimnowski Engineers <br />but not available includes: geotechnical site survey and soil data. If soil conditions, proposed wall layouts, <br />or other design parameters vary from that assumed, a revised analysis may be needed. Please call me if <br />you have any questions or need more information. <br />Independently Owned and Operated <br />161 Dunbar Way / Mahtomedi, MN 55115 <br />O: 651.779.7700 / criterium-schimnowski.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.