Laserfiche WebLink
PROIECT DESCRIPTION <br />The Pipers as property owners are making a request for a conditional use permit in order to <br />construct a detached building for use as a caretaker ’s living quarters. In addition to living <br />quarters this building will also encompass two additional garage stalls as well as additional <br />storage for easy access to outdoor equipment and furniture. The building faUs within a footprint <br />of 24 ’ X 62 ’ and contains 1456 square feet of finished and unfinished space. The proposed <br />structure will be constructed with a concrete slab floor with frost footings, poured concrete <br />foundation and wood frame construction. Finished exterior materials will match the existing <br />home on the site. The proposed building is sited north west of the existing home and is berroed <br />into an existing hillside which serves to minimize the visual impact of the new building as the <br />site is entered. Every effort will be made to preserve the existing trees adjacent to the building <br />area. It will not be necessary to remove any trees to construct this additional building. <br />The existing house will be remodeled. Upgrades to the mechanical systems, window <br />replacement, and augmentation of roof and wall insulation will result in greater energy <br />efficiency. Plan changes will be made to accommodate the needs of the Piper’s as new owners of <br />the home. The reconfigured floor plan results in four sleeping rooms instead of the six sleeping <br />rooms in the existing home. A new screen porch is proposed to be added to the south side of the <br />house as indicated on the registered survey. <br />Since we are proposing to berm the new garage/caretaker building into the existing hillside as <br />shown only as a slight amount of re-grading will be necessary to form a swale to direct site <br />drainage around and alongside the proposed structure. Low, dry-laid stone retaining walls will be <br />installed as indicated on the construction plan to allow berming of site against the north and <br />south elevations of the building as well as creating an egress window well at the south end of the <br />building. Roof water from the proposed structure will drop onto turf and the paved entrance of <br />the garage. This water will be flowed to follow the existing grades of the site, sheeting north <br />easterly across the driveway into the wooded area beyond and below the drive. <br />Grade changes will not be necessary for the proposed screen porch additional to the main house. <br />Additional roof water will drop onto the planting beds to the south side of the existing house as <br />the water percolates toward the lake. <br />The proposed detached garage/caretaker building complies with all setback requirements. See the <br />survey for the exact distances of building comers to property lines. The floor elevation of the <br />new building is 990.5’ which is well above the minimal floor elevation of 945.3 ’. <br />The proposed detached building will have its own septic tank and will be connected by a gravity <br />line to the existing pumping chamber and septic mound. The installation of this new septic tank <br />will also provide an opportunity to upgrade ^e current septic connections for the two toilets and <br />showers and the existing detached poolside building. An alternate drainfield area has been <br />located slightly north and west of the existing drainfield area. <br />• » <br />V <br />/ • <br />.• •• • <br />j V-■w JL <br />1