Laserfiche WebLink
SYSTEM DESIGN <br />FOR TODD ZIESMER <br />IN LOT 20, AUD. SUB. NO. 203 <br />#1341 <br />9-8-88 <br />The above lot %<as tested for both a prijnary and an alternate drainfield <br />site. He first did a soil boring to the south of the proposed house but found <br />a high seasonal %eter table vhich along vdth a steep slope would prevent even <br />a mound system from being installed there. Thus, the area tested was to the <br />north on the level area. This area would require a pressure mound system be­ <br />cause of possible seasonal water tables at a higher level. <br />Additional information follows for the system design. Also, two 1000 <br />gallon tanks are needed with the system. In addition, a 750 gallon pumping <br />tank is needed to house the punp for pressure distribution. It may also bo <br />necessary to have an ejector pump to serve the lower floors. The distribu­ <br />tion pipe coming out under the driveway will need to be insulated. <br />All construction and ireiterials must adhere to the provisions of the <br />City of Orono. All construction traffic and grading must be kept off both <br />the priiraucy and the alternate drainfield sites. <br />If any other information is needed, please contact me. <br />i <br />Sincerely, <br />PERCXDR, INC. <br />PCA certified <br />t.-