My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1987 Septic system design and test report
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2340 Abingdon Way - 03-117-23-23-0015
>
Septic
>
1987 Septic system design and test report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:25 PM
Creation date
2/1/2023 11:49:51 AM
Metadata
Fields
Template:
x Address Old
House Number
2340
Street Name
Abingdon
Street Type
Way
Address
2340 Abingdon Way
Document Type
Septic
PIN
0311723230015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
sxn EVAUimoii kbpoiit <br />FOR vxxxou Momrxts <br />( OART PETERSOK ) <br />OROKCf KXmSOTA <br />5-30.63 <br />m <br />On Kaj U-30* 1963 six psreolstion holts wsro tsstsd on <br />«seh of 10 lets and 3 soil borlnfs token on eoeh lot ss well <br />in oeeordsnee with the provisions of Xndividusl Sewage Sys- <br />ten Trestnent Standards (VFC.U0) adopted in 1976 by the Finn* <br />esota Pollution Control Ageney* Xn addition* other soil bor* <br />ings were taken in lower areas to detemine the possibility <br />of obtaining more than 10 lots but water tables were found <br />to be very high and the soils were found to be very slowly <br />pemeable. <br />According to the soils maps and the information we <br />found in the field* the higher areas had very good soils for <br />drainfields while the lower areas and swales had extremely <br />poor soils for drainfields. Thus* we tended to stick to the <br />higher areas while still leaving room for ample building <br />sites. However* cnee houses are proposed to be constructed <br />it might be desired to shift some of the drainfield areas. <br />Then n w testing would be required and it would be advise- <br />able to keep ls high up 0:1 the kntb? as was previously tes <br />ted. <br />Each site tested '.c.Tuld be acceptable for either a stcn* <br />dard or shallow trench drainfield system and is noted on the <br />attached drawing. It also night be necessary to use inter* <br />ceptor drains to divert runoff water but this would be men-' <br />ticned in the system design for the Individual houses once <br />they ere ready for construction. If any additional informa <br />tion is needed* please contact me. <br />Sincerely* <br />PERCOR* IKC. <br />“^Mark S. Gronberg*
The URL can be used to link to this page
Your browser does not support the video tag.