My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11-15-2004 Planning Packet
Orono
>
Planning Commission
>
2004
>
11-15-2004 Planning Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 1:26:30 PM
Creation date
1/26/2023 1:21:05 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ex.o <br />' . .. j-. . <br />... . ■/ '? .rl <br />Oiiiick 'feport <br />Inspection Address: 3265 Caiman Road <br />Orono, MN <br />Buyers Name: Bonnie Bohn and Mark Hector <br />Date: 05-14-04 <br />Issues: <br />• Minor mold stnins on the noith and west walls of the family room are an indication of <br />past moisture penetration throuph the foundation. Considei adding a ptofessional dram <br />tile system in this area of the basement. <br />• The wood fireplace in the family room has damaged fircbuck in the burn box. a cracked <br />masonry lining in the plenum, a cracked brick wall in the main furnace room and spalling <br />bricks at the top of the chimney. A brick mason should be contacted foi icpaiis Tlw ixrp <br />up damper cable should be adjusted to close properly. <br />• The railroad tic retaining walls at the west side ofthepiojTcrty are at end of life and \ <br />should be rebuilt i <br />* • Tlie lower deck and pool deck have areas of wood lot Total replacement is needed. <br />Eroded soil under the deck should be improver'. . ^ <br />• A cracked and loose slate tde at the front entry should be rcpkaccd <br />• The dirty gutters should be cleaned. <br />• ITtc flexible steel gas line at the clothes dryci should be changed to flexible stainless <br />stcc’. <br />• The GFCI breaker that supplies power to the pool area docs not trip when tested. This <br />should be replaced and proper wiring to all pool equipment verified <br />• GFCI protection should be verined at the master bathroom whiilpool tub. <br />• One outlet at the south wall of the office has a weak ground. <br />• lire furnace humidifier docs not function. <br />• The elcclror.ir air cleaner is inoperative and is now being used as a standard filter. <br />• Ask the seller the function of the blower in tire ceiling of the lower bedroom <br />• The exhaust fan in the upper level hallway has low air f.ow. <br />• Minor caulking is needed at the bathtub in the upper hall batiuooin <br />• This is a beautiful home'! 1 <br />Inspector: GaryVancss <br />.V <br />/ j
The URL can be used to link to this page
Your browser does not support the video tag.