My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
08-23-2004 Council Packet
Orono
>
City Council
>
2004
>
08-23-2004 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 12:34:48 PM
Creation date
1/25/2023 11:45:54 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
b.Any mechanical and utility equipment in a stmcture must be elevated to or <br />above the regulatory flood protection elevation or properly flood proofed; <br />and <br />c. To allow for the equalization of hydrostatic pressure, there must be a <br />minimum of two "automatic" openings in the outside walls of the structure <br />having a total net area of not less than one square inch for every square foot <br />of enclosed area subject to flooding. There must be openings on at least two <br />sides of the strucnire and the bottom of all openings must be no higher than <br />one foot above the lowest adjacent grade to the structure. Using human <br />intervention to open a garage door prior to flooding will not satisfy this <br />requirement for automatic openings. <br />(f) Storage of Materials and Equipment. <br />1. The storage or processing of materials that are, in time of flooding, flammable, <br />explosive, or potentially injurious to human, animal, or plant life is prohibited. <br />2. Storage of other materials or equipment may be allowed if readily removable from <br />the area within the time available after a flood warning and in accordance with a <br />plan approved by the City Council. <br />(g) Flood Control. Structural works for flood control that will change the course, current or <br />cross section of protected wetlands or public waters shall be subject to the provisions of Minnesota Statute, <br />Chapter 103G. Community-wide structural works for flood control intended to remove areas from the <br />regulatory flood plain shall not be allowed in the floodway. <br />(h) A levee, dike or floodwall constructed in the floodway shall not cause an increase to the 100- <br />year or regional flood and the technical analysis must assume equal conveyance or storage loss on both sides <br />of a stream. <br />DfV'ISION 5. FLOOD FRINGE DISTRICT (FF) <br />Sec. 78-1118 Permitted Uses <br />(a) The uses listed in Section 78-1 1 14 of this Ordinance shall be permitted uses. <br />(b) All other permitted uses shall be those uses of land or structures listed as permitted uses in <br />the underlying zoning use district(s). If no pre-existing, underlying zoning use districts exist, then any <br />residential or non residential structure or use of a structure or land shall be a permitted use in the Flood <br />Fringe District provided such use docs not constitute a public nuisance. All permitted uses shall comply with <br />the standards for Flood Fringe District “Permitted Uses” listed in Section 78-1119 and the "Standards for all <br />Flood Fringe Uses" listed in Section 78-1122. <br />Sec. 78-1119 Standards for Flood Fringe Permitted Uses <br />(a) All structures, including accessory structures, must be elevated on fill so that the lowest floor <br />including basement floor is at or above the regulatory flood protection elevation. The finished fill elevation <br />for structures shall be no lower than one (1) foot below the regulatory flood protection elevation and the fill <br />i Distria-t h!ap, UJ/2004 revision -9-
The URL can be used to link to this page
Your browser does not support the video tag.