Laserfiche WebLink
«05-3131 <br />September 15,2005 <br />Page 2 <br />New InformatioD <br />Revised Plan Submitted 9-8-05 . A revised plan was submitted September 9. Staff would note the <br />following items of interest: <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />The proposed cul-de-sac public road has been shitted to the northeast to accommodate <br />additional buildable area within Lot 8, which contains a small wetland. Tliis layout leaves <br />the church with a 60 ’ setback to the road, still meeting its minimum 50 ’ setback requirement. <br />The lot adjacent to the Williamson residence has been converted to an 11,230 s.f. (0.26 acre) <br />Outlot ^^ch satisfies about half of the RPUD 10% private recreation area requirement. <br />Wetland mitigation within the Church parcel (now Lot 2) has been eliminated and the plat <br />proposes 1600 s.f. of wetland filling within Lot 8, which requires MCWD approval. <br />Each of the proposed lots includes at least 14,000 s.f. area as reconunended by the Plaiming <br />Commission. <br />Each lot except for Lot 5 has at least the required 90 ’ of width as measured in a straight line <br />at the propos^ 30 ’ front setback line. Lot 5 has approximately 88’. <br />All but Lots 4 and 7 meet the minimum RPUD lot depth requirement of 125 ’. Lots 4 and 7 <br />are restricted due to the dimensions of the site and the location of the cul-de-sac, leaving <br />them subtly short at about 11 5 ’-120 ’ in depth. The wetland in Lot 8 places some significant <br />restrictions on the functional depth of that lot (see preliminary plat drawing). <br />The RPUD minimum rear yard requirement is 40 ’ or 20% of lot depth, whichever is less. <br />Plans propose a 30 ’ rear yard on Lots 3,4,5,6,9 and 10, which appear to substantially meet <br />the requirement, and 35 ’-45 ’ on Lots 7 and 8, ivhere this greater setback allows the potential <br />to retain or establish a buffer in keeping with the Conservation Design goals (more on this <br />below). The 45 ’ rear setback for Lots 7 and 8 pIso reflects the “Manage 2” wetland <br />protection classification established for this wetland in the new Wetland Ordinance, requiring <br />a 25 ’ buffer and a 20 ’ buffer setback (but see below regarding the combined buffer/setback <br />that is osl being met from the wetland extensions in Lots 7,8,9 and 10...). <br />Each lot appears to have a buildable envelope of 75 ’ x 40 ’ or greater as shown on the <br />submitted plat drawing (this may not be tte case when buffer/setback from wetland <br />extensions is accounted for...). <br />Stormwater ponding is proposed within Outlot A adjacent to Willow Drive, and a smaller <br />pond at the rear of Lot 6. <br />i <br />mm J