% <br />% <br />■ V <br />v) <br />5. <br />6. <br />1. <br />The proposed plat includes six lots. All six lots will be served via a private road to <br />be constructed by the Developer, extending northward along the west property <br />boundary. Each of the 6 lots will have a driveway access from the private road, <br />requiring no new driveway accesses onto Watertown Road. The revised proposal <br />specifically eliminates a building lot at the southeast comer of the property, which <br />would have required a new separate driveway access to Watertown Road, and <br />which would have had the effect of severely interrupting the long natural views <br />into the site as noted in the Rural Oasis study. <br />The potential number of homes to be ultimately served by the private road is more <br />than 6, because the road outlot will extend to the north property boundary to allow <br />for future road connection for development of the property to the immediate <br />north. It would be appropriate to consider whether limiting the paved road width <br />to 24* (instead of the normally required 28 ’ for 7 or more homes) if it can be <br />shown that existing trees that enhance the wooded backdrop can be preserved. <br />The private road will be subject to homeowner association ownership and <br />maintenance, and subject to an underlying Road, Drainage and Utility Easement <br />to be granted to the City. <br />Development as a PRD will allow the creation of an outlot between the wooded <br />backdrop and Watertown Road, litis outlot may contain stormwater ponding to <br />serve the development, and will be covered by a Conservation Easement as well <br />as wetland preservation covenants and easements, wooded area preservation <br />covenants, drainage easements, etc. The intent is to preserve the area of the outlot <br />in as natural a condition as possible with no buildings, roads or other man-made <br />intrusions other than stormwater ponding as necessary to serve the development. <br />Development as a PRT> will allow for slightly smaller lot sizes than nornudly <br />required, which is necessary to allow the relocation of the originally proposed <br />building lot at the southeast comer of the site to a location behind the wooded <br />backdrop. Each of the six lots will have a width of approximately 180’ rather <br />than the 200* RR-IB standard width. Each lot has a proposed building site <br />meeting the RR-IB setback standards (SO* front and rear, 30’ sides). <br />Lots 1,2 and 3, Block 1 will have an average lot area of 1.4 acres rather than the <br />2.0 acres required under the RR-IB standards. This is in part a result of the need <br />to keep homn on the opposite lots in Block 2 above the steeper slopes to the east <br />to die greatest extent possible, wdiich also results in the proposed road location. <br />Due to the smaller lot areas, the three lots in Block 1 will be somewhat limited <br />Page 3 of 13 <br />I1 <br />- -