Laserfiche WebLink
1/J Bonestfoo <br />&j! Rosene <br />Anclerlik& <br />|\|| Associates <br />Digtnttri & ArcMtectt <br />April 29.200S <br />Ms. Janice Gundlach <br />Planner <br />City ofOrono <br />Post Office Box 66 <br />Ciystal Bay, MN SS323 <br />2335 VMest Highway 36 • St. Paul. 55113 <br />Office: 651-636-4600 • Fax; 651-636*1311 <br />wwwiXMiestroo.com <br />EXHIBIT F <br />ClTYo <br />•“a » <br />i 2 ^005 <br />No <br />Re: 174S Fox Street <br />File No. 000I39-0500(M) <br />Plat No. 05-3097 <br />Dear Janice: <br />We have reviewed the site plans dated 4-7-OS for the proposed improvements to 1745 Fox Street The plans <br />propose to subdivide an existing single family lot into a six lot single family subdivision. The existing lot is <br />57.91 acres of which 21.11 acres are dry. We have the following comments with regards to engineering <br />matters: <br />• The drainage calculations provided only address an area (8 acres) that is to be routed to the proposed <br />pond. The city requires that storm water rate control be met for the entire site. In other words, post <br />development flows for the entire site must not exceed predevelopment flows. Drainage calculations <br />should be revised to cover the entire site. It may be necessary to incorporate some best management <br />practices in addition to the pond to meet the rate control required. <br />The propoaed pond needs to meet NURP standards. <br />Because the improvements will disturb more than one acre the final plans should include a detailed <br />temporary and permanent erosion and sediment control plan as required for the NPDES permit. <br />The proposed retaining walls exceed 4-feet in height in some areas. A separate engineered design and <br />detail submittal is required for all walls that are greater than 4-feet in height <br />The limits of the proposed grading for the retaining walls approaches some septic site locations. It is <br />likely that the grading shown will impact the proposed septic sites on Lots 3 and 4. We recommend <br />that the grading plan be revised or alternative septic sites be shown to eliminate any potential conflicts. <br />The driveway shown across Outlot A to serve Lot 6 should be configured to serve the existing guest <br />house if this structure is to remain. The guest house access onto Fox Street should be removed and the <br />ditch regraded. <br />• We received a separate plan dated 4-14-05 proposing improvements to Fox Street to eliminate a sight <br />distance issue, llie plara should be revised to show the existing street grades and include existing <br />vertical curve information so we can further analyrge the necessity of any improvements to Fox Street <br />If you have any questions please call me at (651) 604-4863. <br />Yours very truly, <br />BONESTRCX), ROSENE, ANDERLDC & ASSOCIATES. INC. <br />5*^Tom Kellou <br />Cc: OregGappa.CityofOrono <br />St. Paul, St. Cloud, Rochester, MN • Milwaukee, Wl • Chicago, It <br />Afflmiflttvt Actl«Vt4Ml OppRrtMwHy Iiwplfr an# Implayac Own##