Laserfiche WebLink
#05*3081 Stoiicbay Lofts <br />January 13,200S <br />Pace 3 <br />Building Location and Design Changes <br />Tills new proposal by applicant’s architect Bruce Lelu cr includes many of the elements of llie plan <br />reviewed by the Planning Commission in October2004, but also incoiporales a number of design revisions <br />that were suggested during the October review. Note that: <br />The original approval was for two buildings connected only by the underground parking level, with <br />aterrace level providing significant separation between the two buildings. Tlie current plan, similar <br />to the October2004 plan, connects the two wings above ground. Wliat originally appeared as two <br />separated perpendicular buildings will now appear as a single L-shaped building. To address the <br />Planning Commission’s past comments about reducing the perceived building height and massing, <br />the profile of the southerly wing has been reduced to two levels at the west and east ends, and <br />varyingpeak heights have been added. <br />Highest building peak hei^it, at elev. 1071.33 ’, is liigher tlian tlie 1066.8' peak originally approved <br />in 2002, due in part to the use of 9' ceilings and in part to site drainage considerations that required <br />the lowest floor elevation be raised 3 feet. The current plan’s higliest individual peak is 3 feet lower <br />than the continuous peak reviewed in October. <br />3) The elevation plans incorporate a variety of facade elements and materials wliich help to visually <br />break up the 376' length of the building. <br />The garage level now has a single entrance/exit point, at the east end of the building. A lower- <br />level party room, patio, exercise room and hot tub room have been incoiporated at the interior <br />comer of the garage level, reducing the possible number of stalls in the garage level. <br />5) The west wing completely meets the 80' setback from the adjacent Public Works site as was <br />originally required, with no encroachment of building elements oi decks. <br />Building Design and Location <br />One Building vsTwo Buildings. Tlie two originally proposed 3-story buildings were perpendicular, the fiont <br />building parallel to Kelley Parkway being approximately 260' long by 75' wide, and the peipendicular <br />building being approximately230'x 75'. These were to share a below-grade garage that connected the <br />two buildings, but were visually separated by a distance of about 40-45' above ground. The layout <br />provided for a tciracc between the two buildings, over the garage, providing clear visual separation <br />between the two buildings, which helped to reduce the visual bulk and massing of the two structures.