Laserfiche WebLink
To:Jeanne A. Mabusth, Zoning Administrator <br />From:Thomas J. Jacobs, Senior Building Inspector | <br />Date October 10, 1985 <br />Subjects #982 John Lambin, 3405 Shoreline Drive - <br />Commercial Site Plan Review <br />As per your request I have reviewed this project for items <br />as follows: <br />1. Sprinkler system per Appendix E - maximum square feet <br />1563 s.f. Per Appendix E, sprinkler system required at 2000 <br />s.f. or more. Sprinklers not required at this time. <br />2. Firelanes - see attached drawings. Fire lanes should be <br />posted along front of building (north) and west side of <br />building. This will provide adequate access by fire depart­ <br />ment personal. To eliminate any fire lanes, fire sprinkler <br />system must be installed. <br />3. Hydraunt locations - one hydraunt is about 100' from the <br />east side of the building - two other exist which will cover <br />the building, possibly will need to relay pumps with fire <br />engine. <br />4. SAC Charges - 1 SAC charge exists with the building. <br />The formula for fast food restaurants is: <br />1 SAC per 22 seats <br />The proposed seating is 28 seats thus only 1 SAC is required <br />for the building and it is already paid. <br />5. Sewer and water assessments have all been paid. <br />6. Building - building is structurally sound - must submit <br />plans for building permit and also ‘^et Hennepin County <br />Health Department approval. <br />Maximum square feet 1563 <br />must not exceed 2000 s.f. <br />sprinkler system. <br />any additions to the structure <br />without installation of (fire) <br />K