Laserfiche WebLink
h-. <br />ON-SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />h <br />CITY <br />1 OF <br />I ORONO <br />OWNER U\i\Cr address <br />On the tS'orth Shore of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />PERMIT NO.'S. DATES CONTRACTORS <br />rf f w « V m <br />Citv Ordinance No. 210 require* that each onsite sewage treatment system in Orono be inscected on a regular basis. The on-s.te sewage <br />treatment system at the above address has been insp.-cted and appears to fall into the category checKed below. <br />(This is □ an existing system □ new construction) <br />0^2 <br />Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating <br />properly. <br />upgrading of the system is required at this time. <br />Does not meet current C.ty standards m many respects relating to design, construction, or location. Appears to be operating <br />adwuatcly at this time, but has a relatively h.gn potential for future problems. No ma,or upgrading of system .s required at <br />this time. <br />System may or may not meet current City standards for design, construction or location, but ,s failing to properly treat and <br />dispose of the current input, and .s endangering a water suoplv. or ,s a source of pollution to surface or groundwai.rs. or is <br />creating a safety hazard, or -s otherwise creating a public nuisance. P'ease contact the C-ty Inspector <br />replacement procedures. If drainlield replacement is necessary, soil testing will usually be required, and a design and Site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( G3 Checked items may require your action) <br />Tank inspection indicates: <br />n Pumpout not needed at this lime. <br />□ Solids accumulation in tanks indicates they should be pump­ <br />ed out this year to help prevent future problems. <br />D Solids accumulation in tanks is at a critical levci. Tanks <br />should be pumped out as soon as possible. <br />O System is discharging to surface. Tanks must be pumped <br />jwithin 48 hours to eliminate surface discharge. <br />^^Inspection risers missing—tanks could not be inspected. <br />Inspection risers (4" dia. pipe) must be installed in each tank <br />at next oumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />D InsD'-'ciion pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now <br />Drainf^d inspection indicates; <br />^3I^»’ainfield is dry. no surfacing eviaent. <br />Some evidence of surfacing, not critical yet. <br />□ Drainf.eld is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace* <br />rt'eni or additions to drainfield. Contact the City Inspector <br />immecliatciv. must be compicted wilhm 90 days. <br />□ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />jb Slope <br />□ Soil <br />□ High water table <br />C Lot si/t <br />□ Lake, wetland, or stream <br />□ Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table, and sy:tem condition) <br />□^ow <br />l^Medium <br />□ High <br />G System is causing visible <br />surface discharge. <br />Site Capabilities for <br />Futures xpannon <br />iSAdequdte <br />□ Fair <br />D Poor <br />O Inadequate <br />COMMENTS: <br />alodai' <br />surface oiscnar^c. ^ <br />nacL i/e/i b If I <br />Date of Inspection Septic System Inipector <br />Note- In the event that th.s inspection report is used to satisfy the requ.tements for • mortgege or other transfer of property. ^ <br />J^r/ei^rt ^not guarentee or certify th.t an existing system w.il continue to function properly, but i. nter.ly an opm.on of th. .dequaev <br />of the system under current conditions based on the available information. <br />This rtport must be kept on the premises with system location and pumping records. <br />WHITE COPY / Inspector s File GOLD COPY / Homeowner