Laserfiche WebLink
2815 Casco Point Road, Wayzata, Minnesota <br />November 18, 2022 <br />Page | 7  <br />  <br /> <br /> <br />DESIGN PROVISIONS: <br />1.  REFER TO WOOD RETAINING WALL INDUSTRY GUIDELINES.   <br />2.  SEE PRODUCT MANUFACTURER INSTALLATION RECOMMENDATIONS FOR CONSTRUCTION SEQUENCE  <br />AND INSTALLATION NOTES.  <br />3.  THE DESIGN OF THIS RETAINING WALL SYSTEM WAS BASED UPON THE EFFECTIVE STRENGTH  <br />PARAMETERS SHOWN ON THE “SOIL VALUES” TABLE. UNLESS OTHEWISE NOTED, NO FORMAL SOIL  <br />INFORMATION WAS PROVIDED BY THE OWNER OR OWNER’S REPRESENTATIVE. IF SOIL CONDITIONS  <br />VARY AT TIME OF CONSTRUCTION, WALL ENGINEER MUST BE CONTACTED TO DETERMINE IF A REVISED  <br />DESIGN IS NEEDED.  <br />4. THE WALL DESIGN WAS BASED ON THE INFORMATION NOTED IN THE LETTER ABOVE.  <br />5.  REFER TO WALL CALCULATIONS FOR BEARING CAPACITY REQUIREMENTS.  <br />6. NO PRODUCT/MATERIAL SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN PERMISSION OF  <br />CRITERIUM‐SCHIMNOWSKI ENGINEERS.   <br />7. FINAL SITE GRADES AND ROOF DRAINS SHALL DIRECT RUNOFF AWAY FROM ANY RETAINING WALL(S).  <br />UNLESS OTHERWISE NOTED, THE WALL(S) HAS NOT BEEN DESIGNED FOR HYDROSTATIC SURCHARGE  <br />LOADING.   <br />8.  THE WALL DESIGN WAS PERFORMED USING DESIGN GUIDELINES PRESENTED IN THE THIRD EDITION OF  <br />THE "DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS" PUBLISHED BY NCMA.  <br />DESIGN LIMITATIONS:  <br />1. THE INFORMATION PROVIDED WITHIN THESE DOCUMENTS IS FOR THE STRUCTURAL DESIGN OF THE  <br />PROPOSED RETAINING WALL(S) ONLY.  THE REQUIREMENTS FOR AND/OR WORK RELATED TO  <br />HANDRAILS, GUARDRAILS, OR OTHER LIFE/SAFETY ISSUES ARE EXCLUDED FROM THESE DOCUMENTS  <br />AND ARE TO BE PROVIDED BY OTHERS.  <br />2. SITE LAYOUT AND GRADING DESIGN ARE NOT INCLUDED IN WALL DESIGN SERVICES. THOSE SERVICE  <br />ARE THE RESPONSIBILITY OF THE SITE CIVIL ENGINEER.  <br />3. INTERNAL COMPOUND STABILITY (ICS) HAS BEEN CALCULATED FOR THIS PROJECT BY CRITERIUM.  <br />HOWEVER, ICS IS NOT A SUBSTITUTE FOR A GLOBAL STABILITY ANALYSIS WHICH SHOULD BE  <br />PERFORMED BY A QUALIFIED GEOTECHNICAL ENGINEER. ADDITIONAL SUBSURFACE EXPLORATION MAY  <br />BE REQUIRED.  <br />SUGGESTED QUALITY ASSURANCE REQUIREMENTS:  <br />1. A QUALIFIED ENGINEER OR TECHNICIAN SHALL SUPERVISE THE WALL CONSTRUCTION TO VERIFY SITE  <br />SOIL CONDITIONS.  IF THE PROJECT GEOTECHNICAL ENGINEER DOES NOT PERFORM THIS WORK, A  <br />QUALIFIED GEOTECHNICAL ENGINEER/TECHNICIAN SHALL BE HIRED TO ASSURE THE RETAINING WALL IS  <br />CONSTRUCTED WITH PROPER SOIL PARAMETERS.  <br />2. A QUALIFIED GEOTECHNICAL ENGINEER SHALL BE CONSULTED TO VERIFY THE SUITABILITY OF DESIGN  <br />ASSUMPTIONS MADE BY CRITERIUM.  <br />3. WALL EXCAVATION AND SOILS SHALL BE INSPECTED FOR GROUNDWATER CONDITIONS. THE  <br />GEOTECHNICAL ENGINEER SHALL DETERMINE ADDITIONAL DRAINAGE PROVISIONS TO BE  <br />INCORORATED INTO THE WALL DESIGN.   <br />4. THE WALL DESIGN ENGINEER SHALL BE HIRED TO PERFORM A PRE‐CONSTRUCTION SITE VISIT.  <br />5. THE WALL DESIGN ENGINEER CAN BE HIRED FOR CONSTRUCTION OBSERVATION SERVICES.   <br />6. THE WALL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING QUALITY CONTROL FOR THE  <br />CONSTRUCTION OF THE WALL IN ACCORDANCE WITH CONTRACT REQUIREMENTS.  <br />7. SEE PROJECT CONTRACT DOCUMENTS FOR SPECIFIC DETAILS ON THE SCOPE OF WORK THAT WILL BE  <br />PROVIDED BY ALL PARTIES. <br /> <br />