My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
230 Big Island - PID: 23-117-23-23-0033
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:48 PM
Creation date
9/22/2015 1:22:50 PM
Metadata
Fields
Template:
x Address Old
House Number
230
Street Name
Big Island
Address
230 Big Island
Document Type
Septic
PIN
2311723230033
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> \ � <br /> O� <br /> � <br /> O :��.� O <br /> -?'`�` �ITY of OROI�TO <br /> ��r.,.:�� <br /> � ' ''�#��: �--� <br /> �1��� ;�`,�� ,�+ <br /> , ;;,� ti MunicipalO�ces <br /> `�' ��"�.��'�_' a� "ti <br /> �.Z �`�,`;'����C`�`�`.�y� Street Address: Mailing Address: <br /> 9 '�,,P�" .¢ <br /> k'E*gK0 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay; MN 55323-0066 <br /> Owner: N����/ ��� �25 Address:_ a30 U�q �S�q�d <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site se�vage treatment system at the abo��e address has been inspected and appears to fall into the categories checked belo���. <br /> SYSTEM CONFORMITY (1-3): 3 <br /> 1 '�CODE SYSTEM° An ISTS which meets all the location,design and construction standards of the current Orono btunicipal Code. <br /> 2 °C01�1PLIANT SYSTEM�� An ISTS which does not meet all the location,design and construction standards oftfie cuirent Orono Municipal <br /> Code but dors meet the threz foot sepazation requirement,and which is not failing or an inuninent threat to public heahh or safzty. <br /> O3 °NON-COMPLIANT SYSTEM° A prohibited ISTS;an ISTS locatzd within a drsigiated 100-yeaz flood plain,any ISTS which may <br /> or may not mzet all the location,design,or construction standards of the current Orono,�ilunicipal Code and which is fuling for any reason;and <br /> any ISTS with lus than thrze fzzt of unsaturated soi(or sand bet�veen tha distribution device and the limiting soil charaderistics. <br /> TANK CONDITION(5-101: <br /> Tank inspection indicates: <br /> � Pumpout nut needed at this time. <br /> f) Tank must be pumped out this year (city code requires tanks to be pumpzd out evzry 3 years. Tank was last pumped ��k nOw r1 �, <br /> � Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. <br /> 8 Systzm is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Irupzction riszrs missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must ba installzd in each tank at nzst pumpout If tanks <br /> have not bzzn pumped out within the last three years,ihey should be pumped out now. <br /> 1� Inspection pipz is located duectly over tank ba81e(dozs not give accurate measurement of solids accumulation). Iftanks have not been pumped <br /> out within the last three years,thzy should be pumped out now. <br /> DRATVFIELD CO�IDITION(11-14): � �-( <br /> 11 Drainfizld is dry,no surfacing evident <br /> ' 1� Some ecidznce of surfacing,not critical yzL � , <br /> 13 Drainfield is saturated and visibly dischazging untteatzd e�luent to ihe surfacz. Contact the City Inspector immediatzly.Rrpairs must be <br /> complzted within 90 days. <br /> 1=� Drainfield estent and condition unknown. <br /> COMN�NTS: Sy 5fie�-, �oe5 r�o fi rneefi 3 �oafi Se(�e�q-��o� �,Sfi�,�ce <br /> Rep\g�� by �a-3� -o �. . <br /> '�-�3 -o � �1�. <br /> Date of Inspeclion Seplic System Inspector <br /> Note: In the everrt that this irLspzction repoR is used to satisfy the requiremenLs for a mortgage or other transfer of property,be advised that this report does not guarantze <br /> or certify that an existing systzm will continue to function properIy,but is mzrely an opinion of the adequacy of the system under cuseut conditions based on the available <br /> informalioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.