My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Insulation
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
180 Big Island - PID: 23-117-23-23-0036
>
Land Use
>
Insulation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:57 PM
Creation date
9/18/2015 3:12:29 PM
Metadata
Fields
Template:
x Address Old
House Number
180
Street Name
Big Island
Address
180 Big Island
Document Type
Land Use
PIN
2311723230036
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROJECT NO: 4140 92-2757 DATE: July 23, 1993 <br /> PAGE: 5 <br /> TEST �tETHODS: 1 <br /> TestinQ <br /> All tests were conducted as referenced in ASTNi:C578-87a. <br /> am lin <br /> Two 4' x 8' sheets of EPS thermal insulation were submitted for each ASTM C578 classification of EPS <br /> insulation evaluated. Each 4' x 8' sheet was sub-divided into two 2' x 8' sheets. One of these was used <br /> as the control, for testing of initial properties. The other three were applied to the foundation wall. One <br /> sample of each EPS type was removed annually over the next three years. <br /> From each 2' x 8' sample removed, three 12" x 12" specimens were tested for density and thermal <br /> resistance. One near the top of the 8' length, one near the bottom, and one near the center. <br /> Sample Installation ' <br /> The test samples were applied to the exterior of the below grade foundation of Twin City Testing's <br /> , Cromwell Avenue building on September 21, 1989. The temperature on the inside of this foundation wall <br /> � is maintained at 70±5°F. Three 2' by 8' pieces of ASTM C578 type I and type II EPS were installed with <br /> the 8' length vertical. The top of each sample was placed just under ground level and the samples were <br /> held in place by back fill. The soil used to back.fill has a final grade of '/z" per foot and had the following <br /> characteristics: <br /> Classification: Sand with silt and gravel, medium to fine grain. <br /> Density, lb/ft': � 112.3 � <br /> Moisture Content, %: 7.9 (1.06 gallons water/ft3 soil) <br /> Coefficient of Permeability <br /> at 20°C, fVmin: 6.0 x 10-3 <br /> Mechanical Analysis <br /> Percent Finer Than: 3/4" 100.0 <br /> 3/8" 96.1 <br /> f�4 90.3 <br /> �10 82.9 <br /> #40 35.4 <br /> #100 14.9 <br /> ' /l200 10.9 <br /> aS A 4tU�Ual PRCTcC��ON TO CUENTS THE PUBUC AND OURScLVES.AlL iDVIN GTV TESTING CORPOR4iiON REPORTS a�E SUBM�TTED AS TME CONFIOENTiAL PROPERTV OP rUE'7T5 <br /> ATJO aU�MC�7QA71ON:OR PU9l'GTIGN Of S��1T��,1ENiS.CONCIUS�ONS OA EXTqqCT10N5 F�70M OR GiEGnRDING OUR REPORTS IS RESERVED PENOWG OUR PFIOR WRITT�;V A?oq0`:AL <br />
The URL can be used to link to this page
Your browser does not support the video tag.