Laserfiche WebLink
Page 14 of 14 National Evaluation Report No. NER-520 <br /> Foatnotes for Figure 2 -Floor/Ceiling and RooflCeiling Assembly-One Hour <br /> 1. Insulspan Panels-48 inches(1220 mm)wide(minimum),5-1/2 inch(88.9 mm)thick(maximum)EPS core having 7/16 inch <br /> (11.1 mm) thick OSB skins. Panels having 7-1/4, 9-1/4 and 11-1/4 inch thick cores are also permitted in roof/ceiling <br /> assemblies. <br /> 2. Splines-2x wood spline studs.When the tables indicate that no spline studs are required for structural capacity,3 inch(76.2 <br /> mm)wide, 5/8 inch (15.9 mm)thick OSB surface splines are permitted under both skins instead of spline studs. <br /> 3. Fasteners-OSB skins are fastened to spline studs using 6d nails @ 6 inches(152 mm)on center.When using OSB surface <br /> splines, the surface splines shall be installed using a gap filling expanding foam sealant and 1 inch (25.4 mm) long, No. 6 <br /> drywall screws at 6 inches (152 mm) on center on each side of the joint. <br /> 4. Gypsum Wallboard -a ceiling surface consisting of two layers of 5/8 inch (15.9 mm)thick Type X gypsum wallboard. The <br /> gypsum panels are attached to the Insulspan panels using 2 inch (51 mm) long, A-point, bugle head drywall screws at 6 <br /> inches (152 mm) on center along the sheet perimeters and on a 12 inch (304 mm) x 12 inch (304 mm) spacing in the field <br /> of the sheets.All seams shall be staggered. Exposed seams shall be treated with an application of tape,followed by three <br /> coats of US Gypsum Corporation Durabond 90 joint compound. <br /> 5. Roof Covering - (on roof/ceiling assemblies only) -a code complying roof covering. <br /> Faotnotes for Figure 3-Wall Assembly-One Hour(Limited Load Bearing) <br /> 1. Insulspan Panels-3-1/2 inch(88.9 mm)or 5-1/2 inch(140 mm)thick EPS core having 3/8 inch(9.52 mm)or 7/16 inch(11.1 <br /> mm)thick OSB skins. Structural load shall not exceed 27.4 % of allowable load nor 1250 Ib/ft(18.2kN/m). <br /> 2. Splines-2x wood studs @ 48 inches (1220 mm) on center. <br /> 3. Top and Bottom Plates-2X wood top and bottom plates. <br /> 4. Nails-OSB skins are fastened with 6d common nails at 6 inches(152 mm)on center at panel edges(vertical splines)and <br /> at top and bottom plates. <br /> 5. Gypsum Wallboard -Two layers of 1/2 inch (12.7 mm) thick USG FireCode "C" installed on each side of the assembly. <br /> Installation of wallboard on the interior side only of exteriorwalls is permitted in jurisdictions using the Standard Building Code <br /> or the BOCA/National Building Code when such walls are located greater than 5 feet 1524 mm) from a property line or <br /> assumed property line. <br /> The first layer of gypsum wallboard is installed horizontally over the Insulspan panels using a continuous 3/8 inch diameter <br /> bead of construction adhesive(Miracle DSA 20 drywall adhesive)at 24 inches (609 mm) on center across the width of the <br /> panels and 1 inch (25.4 mm)long No. 6 bugle head drywall screws at 8 inches 203 mm)on center along the perimeter and <br /> 12 inches (304 mm) on center at the two adhesive lines. <br /> The second layer of gypsum wallboard is installed vertically in the same manner as the first layer using 1-5/8 inch(41.3 mm) <br /> long bugle head drywall screws. <br /> 1_0 SUBJEGT 3_0 DESCRIPTION 6_0 EVIDENCE SUBMITTED <br /> 2.0 PROPERTY FOR WHICH 4.0 INSTALLATION 7.0 CONDITIONS OF USE ' <br /> EVALUATION IS SOUGHT 5_0 IDENTIFICATION <br /> Re-fssued November 1, 2002 NES <br /> back to the NES home paqe National Evaluation Service, Inc. Product Evaluation Listinp <br /> Copyright0 2002 <br />