My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic inspections
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
170 Big Island - PID: 23-117-23-23-0029
>
Septic
>
Septic inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:43 PM
Creation date
9/17/2015 1:56:33 PM
Metadata
Fields
Template:
x Address Old
House Number
170
Street Name
Big Island
Address
170 Big Island
Document Type
Septic
PIN
2311723230029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.�, o,�,. <br /> - � o 0 <br /> ' ===-Y .�-� C ITY of OR�NO <br /> Ij , �:r� � � <br /> ,� yi '� `�, <br /> '�+� �..,�� .�.._: ';� ,�,FY Municipat Offices <br /> � `` ��'����,r`,�ti G <br /> l �' ' '`<7'��� «` Street Address: Mailing Address: <br /> ,,q � ,.��:,,� :g,� <br /> �CEggO 2150 Kelley Parfcway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: J 0 S�p �1 u q C.K�'� Address: I ?� l.� �q �S �`��^� <br /> Cin�Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site se«�age treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> S�'STEM CONFORMIT'Y (1-3): � <br /> � ��CODE SYSTEM" An ISTS which mzets all thz location,design and construction standards ofthe cucrent Orono Municipal Code. <br /> \J <br /> 2 ��COMPLIANT SYSTEM" An ISTS which does not meet a(1 the location,design and construction standards ofthe cuirent Orono Municipal <br /> Code but does meet thz three foot separation requirement,and which is not failing or an irruninent threat to public health or safety. <br /> 3 ��NON-COMPLIANT SYSTEM" Aprohibited ISTS;an ISTS locatzd within a designated 100-year flood plain,any ISTS which may <br /> or may not mzet all the localioq dzsigi,or construction standards of the current Orono Municipal Code and which is failing for any reuon;and <br /> any ISTS with less than thtte feet oFunsaturated soil or sand between the distribution davice and the limiting soil characteristics. <br /> TANf�CONDITION(�-10): I O <br /> Tank inspection indicates: - <br /> � Pumpout not needed at this time. <br /> � Tan1:must bz pumped out this year (city code requires tanks to be pumpzd out every 3 years. Tank was I�st pumped �,11�K!�p W n ). <br /> �/ Solids accumulation in tanks is at a critical a critica((evaL Tanks shou(d be pumped out az soon as possiblz. <br /> S Systzm is discharging to tht surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not bz inspected. Inspection riszrs(4"dia.pipe)must be installed in each tank at neM pumpout If tanks <br /> ha��e no[brzn pumped out within the last thtez yzars,thzy should be pumped out now. <br /> 1� Inspaction pipa is loca[zd dirzcdy over tank ba$le(does not give accurate measurement of solids accumulalion). If tanks have not been pumped <br /> out within the last three years,they should be pumpad out now. <br /> DRAINFIELD CONDITION(11-14): � � <br /> 1 1 Dra�eld is dry,no surfacing tvident <br /> 1� Some e�'idence of surfacing,not critical yet � • <br /> 13 Drainfield is saturated and visibly discharging untraated e&luent to the surface. Contact the City Inspector immediately.Repairs must be <br /> complated��ithin 90 days. <br /> 1� Draintizld e�tent and condition unknown. <br /> CO�uL�NTS: S� Ste M �'S-i' ��nS �t���c� '�- �� , l.� v*^ � �--i-�-��.� <br /> �a5� 3 ye�.cS p� ,,�, p� �•v, b� ��kS no} neeclee . <br /> ��� � � � 4� �/���2J'rv.�,,,� <br /> Date of Inspection Septic System Inspector <br /> \otz: In the event that this inspection report is uszd to satisfy the requuemznis for a moRgage or other transfer of property,be advised that this report does not guarantze <br /> or ceRify that an eusting system will continue to funetion propetiy,but is merely an opinion of the adequacy of the system under cucrent conditions bazed on the available <br /> informatioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.