Part 1 of Sigel wall design 2007
Orono
>
Property Files
>
Street Address
>
P
>
Park Drive
>
1399 Park Drive - 07-117-23-42-0012
>
Permits/Inspections
>
Part 1 of Sigel wall design 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:38:09 PM
Creation date
10/19/2022 2:54:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1399
Street Name
Park
Street Type
Drive
Address
1399 Park Dr
Document Type
Permits/Inspections
PIN
0711723420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
March 20, 2007 <br />Project No. 07-0223 <br />To: Steve Sigel <br />1399 Park Road <br />Orono, MN 55364 <br />MSE.Mortaring <br />M Mflnipn Fm <br />Subject: Segmental Retaining Wall Design and Analysis, Sigel Residence, 1399 <br />Park Road, Orono, MN. <br />In accordance with your request, Mortarless Systems Engineering (MSE) has prepared a <br />design and analysis of the segmental retaining wall's (SRW's) proposed for your <br />Residence, 1399 Park Road, Orono, MN. <br />Based upon our retaining wall analyses, it is MSE's opinion that the subject proposed <br />SRW's will be internally and externally stable provided the specific recommendations <br />contained herein this report, and the general construction recommendations of Anchor's <br />Concrete Segmental Retaining Wall System specifications, are incorporated in the <br />construction of the subject SRW's. <br />Backfill used in the reinforced zone shall meet the requirements in Anchor's Concrete <br />Segmental Retaining Wall System specifications item 2.01 E. <br />Internal drainage systems, other than the minimum 12" of drainage rock behind the block, <br />are not required. However, if seepage is encountered in the backcut during the course of <br />construction, additional drainage systems may be required. <br />4MA I C� ° FESS <br />QRO /ON <br />Cameron Roberson, PE 43483 ��� pN Rp qIe <br />e��'J' tic a <br />Enclosed: Anchor's Specifications Q O m <br />Wall Calculations <br />w U No. 43483 Z <br />Typical Details Quo' <br />Wall Plan and Profiles <br />�lP OF MINN�S. <br />Copy: (4) Addressee <br />(1) Engineering Department <br />, <br />325 Alliance Place NE, Rochester, MN 559136-3975 • phone 507.535.3526, fax 507.52 'e7 'ai m rtarless.nr±t <br />