STRUCTURAL NOTES <br /> MATERIAL STRENGTHS <br /> Reinforcing Steel Fy = 60,000 p.s.i. (A615 grade 60) <br /> Concrete F'c = Compressive strength in 28 days <br /> 3,000 p.s.i.for footings <br /> DESIGN LIVE LOADS <br /> Roofs 50 p.s.f. ground snow load <br /> Typical Floors 40 p.s.f. <br /> Basic Wind Speed 90 m.p.h. (3 second gust) <br /> DESIGN CODES - LATEST EDITIONS <br /> International Building Code <br /> Minnesota State Building Code <br /> American Concrete Institute <br /> CRSI Manual of Standard Practice <br /> American Institute of Timber Construction <br /> National Design Specifications for Stress-Graded Lumber and its Fastenings <br /> SOIL BEARING DESIGN VALUE <br /> 2,000 p.s.f. on undisturbed soil or compacted fill for footings. <br /> Bearing value to be verified by a geotechnical engineer. <br /> EXISTING CONDITIONS <br /> Verify all dimensions, elevations, and details of existing structures where they affect this <br /> construction. Notify engineer if there are any deviations from the contract documents. Field <br /> verify dimensions and elevations prior to fabrication of structural members. <br /> TEMPORARY BRACING <br /> Provide temporary lateral support for all walls until walis are adequately braced by floor or roof <br /> structure. <br /> FOOTINGS <br /> Wall footings are cast-in-place concrete with continuous reinforcing placed 3"clear of bottom and <br /> sides. Unless otherwise noted, wall footings are centered under walls and column footings under <br /> columns. Footings for walis, unless otherwise noted, shall be 10" thick with a minimum projection <br /> of 4" each side with 2 -#4 continuous. <br /> DIMENSION LUMBER <br /> Dimension lumber shall be No. 2 hem Fir or equal for joists, beams and headers. Wall studs shall <br /> be Stud Grade SPF or equal. Spacing of bridging for joists shall not exceed 8'-0". Wood lintels <br /> and headers shall have a full 1%2" length of bearing at each end unless notes otherwise. Double <br /> all joists under parallel partitions. All beams and joists not bearing on supporting members shall <br /> be framed with "Simpson Strong-Tie"joist hangers or equal. Interior walls to have 2x4 studs at <br /> 16" on center. Exterior walls to have 2x6 studs at 16"on center. <br />