My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
130 Big Island - PID: 23-117-23-22-0002
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:30 PM
Creation date
9/16/2015 3:22:44 PM
Metadata
Fields
Template:
x Address Old
House Number
130
Street Name
Big Island
Address
130 Big Island
Document Type
Septic
PIN
2311723220002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> � • <br /> � O� <br /> O����� O <br /> :x.`�:� CITY of O]�011T0 <br /> ��....: a <br /> '���`l `-�' �, <br /> � ���' �,���. <br /> . <br /> y� h"� ti Municipal Offices <br /> �� ��;`r,,�,����;����y G'� <br /> � �i�`r`���'st-���`.� Street Address: Mailing Address: <br /> � 11'. �1 I Q <br /> $'Z,`$$Of 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay; MN 55323•0066 <br /> Owner: M��- q�('efi S�I,e �-fi�,� Address:_ 130 Q;q �SlqncJ <br /> Ciry Ordinance 199 requires that each existing on-site sewage treatrnent system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.' <br /> SYSTEM CONFORMITY (1-3): 3 <br /> 1 ��C�DE SYSZ EIV1�� An ISTS which mzets all the location,design and construction standazds ofthe cucrent Orono bfunicipal Codz. <br /> 2 ��CO�TPLIANT SYS'I'EM�� An ISTS which does not mezt all the location,design and construction standards ofthe current Orono Municipal <br /> Code but does meet the three foot sepuation requiremznt,and which is not failing or an imminent threat to public heahh or safety. <br /> 3O °NON-CO�LIANT SYSTEIvI" A prohibited ISTS;an ISTS located within a designated 100-yeat flood plaiq any ISTS which may <br /> or may not meet all the localion,design,or construction standards of the cuirent Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three fezt of unsaturatzd soil or sand betwezn the distribution device and the limiting soil chazaderistics. <br /> TANI�CONDITION(�-10): q - <br /> Tank inspection indicates: <br /> � Pumpout nut needed at this timz. <br /> E> Tank must be pumped ou[this qzar (city code requires tanks to be pumpzd out zvery 3 years. Tank was last pumped_V r�k r�0 W r� ). <br /> 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. <br /> s Systzm is discharging to the surface. Tanks must be pumped out within 48 hours to zliminate surface discharge. <br /> OInspection risers missing-tanks could not bz inspzeted. Inspection riszrs(4"dia.pipe)must ba installed in each tank at nzst pumpout If tanks <br /> have not been pumped out within the last three years,they should be pumped out now. <br /> 1� Inspection pipz is located ditectly over tank ba$1e(does not give accurate measurzment of so(ids accumulation). Iftanlcs have not been pumped <br /> out within the last three yzars,:hey should be pumped out now. . <br /> DRAINFIELD CONDITION(11-14): 1 I <br /> � I?rlutFeld is dry,no surfacing ecident <br /> 1� Some evidznce of surfacing,not critical yeG • , <br /> 13 Dn�zld is saturated and visibly dischazging untrzated effluznt to the surface. Contact the City Inspector irrunediately.Rtpairs must be <br /> completed uithin 90 da}�s. <br /> 1=� Drainfield z�ttent and condition unknown. <br /> COMN1ENTs:_ S�sfie� C�oes �ot Me��r 3 �oafi sep�.�c�fi,o� ��st�+nce , <br /> Rep`q�� b� ►a-3�- o7. . ' <br /> s-�_o� �-�,1� � <br /> Date of Inspection Septic System Inspector ' <br /> Note: In the event that this inspection repoR is used to satisfy the requuements for a moRgage or otha truufer of ptoperty,be ad�ised that this report does not guarantee <br /> or cMify that an esisting system will continue to function properly,but is merely an opinion of the adequacy of the systzm under cuire�conditions based on the available <br /> infocmalion. <br />
The URL can be used to link to this page
Your browser does not support the video tag.